The ePix10k 2-megapixel hard X-ray detector at LCLS
-
Published:2020-04-17
Issue:3
Volume:27
Page:608-615
-
ISSN:1600-5775
-
Container-title:Journal of Synchrotron Radiation
-
language:
-
Short-container-title:J Synchrotron Radiat
Author:
van Driel Tim Brandt, Nelson Silke, Armenta Rebecca, Blaj Gabriel, Boo Stephen, Boutet SébastienORCID, Doering Dionisio, Dragone Angelo, Hart Philip, Haller Gunther, Kenney Christopher, Kwaitowski Maciej, Manger Leo, McKelvey Mark, Nakahara Kaz, Oriunno Marco, Sato TakahiroORCID, Weaver Matt
Abstract
The ePix10ka2M (ePix10k) is a new large area detector specifically developed for X-ray free-electron laser (XFEL) applications. The hybrid pixel detector was developed at SLAC to provide a hard X-ray area detector with a high dynamic range, running at the 120 Hz repetition rate of the Linac Coherent Light Source (LCLS). The ePix10k consists of 16 modules, each with 352 × 384 pixels of 100 µm × 100 µm distributed on four ASICs, resulting in a 2.16 megapixel detector, with a 16.5 cm × 16.5 cm active area and ∼80% coverage. The high dynamic range is achieved with three distinct gain settings (low, medium, high) as well as two auto-ranging modes (high-to-low and medium-to-low). Here the three fixed gain modes are evaluated. The resulting dynamic range (from single photon counting to 10000 photons pixel−1 pulse−1 at 8 keV) makes it suitable for a large number of different XFEL experiments. The ePix10k replaces the large CSPAD in operation since 2011. The dimensions of the two detectors are similar, making the upgrade from CSPAD to ePix10k straightforward for most setups, with the ePix10k improving on experimental performance. The SLAC-developed ePix cameras all utilize a similar platform, are tailored to target different experimental conditions and are designed to provide an upgrade path for future high-repetition-rate XFELs. Here the first measurements on this new ePix10k detector are presented and the performance under typical XFEL conditions evaluated during an LCLS X-ray diffuse scattering experiment measuring the 9.5 keV X-ray photons scattered from a thin liquid jet.
Funder
US Department of Energy, Office of Science
Publisher
International Union of Crystallography (IUCr)
Subject
Instrumentation,Nuclear and High Energy Physics,Radiation
Reference29 articles.
1. AGIPD, a high dynamic range fast detector for the European XFEL 2. The X-ray Correlation Spectroscopy instrument at the Linac Coherent Light Source 3. Femtosecond X-Ray Scattering Study of Ultrafast Photoinduced Structural Dynamics in Solvated[Co(terpy)2]2+ 4. X-ray detectors at the Linac Coherent Light Source 5. Blaj, G., Caragiulo, P., Carini, G., Dragone, A., Haller, G., Hart, P., Hasi, J., Herbst, R., Kenney, C., Markovic, B., Nishimura, K., Pines, J., Segal, J., Tamma, C. & Tomada, A. (2016). AIP Conf. Proc. 1741, 040012.
Cited by
32 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|