X-ray photon diagnostics at the European XFEL
-
Published:2019-08-02
Issue:5
Volume:26
Page:1422-1431
-
ISSN:1600-5775
-
Container-title:Journal of Synchrotron Radiation
-
language:
-
Short-container-title:J Synchrotron Radiat
Author:
Grünert Jan, Carbonell Marc Planas, Dietrich Florian, Falk Torben, Freund Wolfgang, Koch Andreas, Kujala Naresh, Laksman JoakimORCID, Liu Jia, Maltezopoulos Theophilos, Tiedtke Kai, Jastrow Ulf Fini, Sorokin Andrey, Syresin Evgeny, Grebentsov Alexander, Brovko Oleg
Abstract
The European X-ray Free-Electron Laser (European XFEL) (Altarelli et al., 2006; Tschentscher et al., 2017), the world's largest and brightest X-ray free-electron laser (Saldin et al., 1999; Pellegrini et al., 2016), went into operation in 2017. This article describes the as-built realization of photon diagnostics for this facility, the diagnostics commissioning and their application for commissioning of the facility, and results from the first year of operation, focusing on the SASE1 beamline, which was the first to be commissioned. The commissioning consisted of pre-beam checkout, first light from the bending magnets, X-rays from single undulator segments, SASE tuning with many undulator segments, first lasing, optics alignment for FEL beam transport through the tunnel up to the experiment hutches, and finally beam delivery to first users. The beam properties assessed by photon diagnostics throughout these phases included per-pulse intensity, beam position, shape, lateral dimensions and spectral properties. During this time period, the machine provided users with up to 14 keV photon energy, 1.5 mJ pulse energy, 300 FEL pulses per train and 4.5 MHz intra-bunch train repetition rate at a 10 Hz train repetition rate. Finally, an outlook is given into the diagnostic prospects for the future.
Publisher
International Union of Crystallography (IUCr)
Subject
Instrumentation,Nuclear and High Energy Physics,Radiation
Reference36 articles.
1. Altarelli, M., Brinkmann, R., Chergui, M., Decking, W., Dobson, B., Düsterer, S., Grübel, G., Graeff, W., Graafsma, H., Hajdu, J., Marangos, Jonathan, Pflüger, J., Redlin, H., Riley, D., Robinson, I., Rossbach, J., Schwarz, A., Tiedtke, K., Tschentscher, T., Vartaniants, I., Wabnitz, H., Weise, H., Wichmann, R., Witte, K., Wolf, A., Wulff, M. & Yurkov, M. (2006). The European X-ray Free-Electron Laser Technical Design Report. DESY Report 2006-097. DESY, Hamburg, Germany. 2. Duty-cycle dependence of the filamentation effect in gas devices for high repetition rate pulsed x-ray FELs 3. Freund, W. (2011). European XFEL Technical Note. XFEL.EU TN-2014-001-01. European XFEL Facility, Hamburg, Germany. 4. Freund, W., Grünert, J., Liu, J., Karabekyan, S. & Koch, A. (2018). Proceedings of the 13th International Conference on Synchrotron Radiation Instrumentation (SRI2018), 11-15 June 2018, Taipei, Taiwan. AIP Publishing. In the press. 5. Scientific instrument Femtosecond X-ray Experiments (FXE): instrumentation and baseline experimental capabilities
Cited by
30 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|