Double-multilayer monochromators for high-energy and large-field X-ray imaging applications with intense pink beams at SPring-8 BL20B2
-
Published:2022-07-15
Issue:5
Volume:29
Page:1265-1272
-
ISSN:1600-5775
-
Container-title:Journal of Synchrotron Radiation
-
language:
-
Short-container-title:J Synchrotron Radiat
Author:
Koyama TakahisaORCID, Senba YasunoriORCID, Yamazaki Hiroshi, Takeuchi Tomoyuki, Tanaka Masayuki, Shimizu Yasuhiro, Tsubota Koji, Matsuzaki Yasuhisa, Kishimoto Hikaru, Miura Takanori, Shimizu Satsuki, Saito Takamitsu, Yumoto Hirokatsu, Uesugi KentaroORCID, Hoshino MasatoORCID, Yamada JumpeiORCID, Osaka TaitoORCID, Sugahara Michihiro, Nariyama NobuteruORCID, Ishizawa Yasuhide, Nakano Hiroko, Saji ChojiORCID, Nakajima Kyo, Motomura Koji, Joti YasumasaORCID, Yabashi MakinaORCID, Ohashi HaruhikoORCID
Abstract
In this study, double-multilayer monochromators that generate intense, high-energy, pink X-ray beams are designed, installed and evaluated at the SPring-8 medium-length (215 m) bending-magnet beamline BL20B2 for imaging applications. Two pairs of W/B4C multilayer mirrors are designed to utilize photon energies of 110 keV and 40 keV with bandwidths of 0.8% and 4.8%, respectively, which are more than 100 times larger when compared with the Si double-crystal monochromator (DCM) with a bandwidth of less than 0.01%. At an experimental hutch located 210 m away from the source, a large and uniform beam of size 14 mm (V) × 300 mm (H) [21 mm (V) × 300 mm (H)] was generated with a high flux density of 1.6 × 109 photons s−1 mm−2 (6.9 × 1010 photons s−1 mm−2) at 110 keV (40 keV), which marked a 300 (190) times increase in the photon flux when compared with a DCM with Si 511 (111) diffraction. The intense pink beams facilitate advanced X-ray imaging for large-sized objects such as fossils, rocks, organs and electronic devices with high speed and high spatial resolution.
Publisher
International Union of Crystallography (IUCr)
Subject
Instrumentation,Nuclear and High Energy Physics,Radiation
Reference20 articles.
1. Chantler, C. T., Olsen, K., Dragoset, R. A., Chang, J., Kishore, A. R., Kotochigova, S. A. & Zucker, D. S. (2005). X-ray form factor, attenuation and scattering tables (Version 2.1) [Online]. Available: http://physics.nist.gov/ffast [14 January 2022]. Gaithersburg, MD: National Institute of Standards and Technology. 2. Performance of a double-multilayer monochromator at Beamline 2-BM at the Advanced Photon Source 3. Fast microtomography using high energy synchrotron radiation 4. Construction and commissioning of a 215-m-long beamline at SPring-8 5. Hoshino, M., Uesugi, K., Shikaku, R. & Yagi, N. (2017). AIP Adv. 7, 105122.
Cited by
7 articles.
订阅此论文施引文献