Synchrotron CT of an equine digit at the Australian Synchrotron Imaging and Medical Beamline

Author:

Montgomery J. B.ORCID,Klein M.,Boire J. R.ORCID,Beck C.ORCID,Häusermann D.,Maksimenko A.,Hall C. J.

Abstract

Laminitis is an extremely painful and debilitating condition of horses that can affect their athletic ability and even quality of life. The current gold standard for assessment of laminar tissue is histology, which is the only modality that enables detailed visualization of the lamina. Histology requires dissection of the hoof and therefore can only represent one specific time point. The superior spatial and contrast resolution of synchrotron computed tomography (sCT), when compared with readily available imaging modalities, such as radiographs and conventional CT, provides an opportunity for detailed studies of the lamina without the need for hoof dissection and histological assessment. If the resolution of histology can be matched or even approached, dynamic events, such as laminar blood flow, could also be studied on the microscopic tissue level. To investigate this possible application of sCT further, two objectives are presented: (i) to develop a protocol for sCT of an equine digit using cadaver limbs and (ii) to apply the imaging protocol established during (i) for sCT imaging of the vasculature within the foot using an ex vivo perfusion system to deliver the vascular contrast. The hypotheses were that sCT would allow sufficient resolution for detailed visualization to the level of the secondary lamellae and associated capillaries within the equine digit. Synchrotron CT enabled good visualization of the primary lamellae (average length 3.6 mm) and the ex vivo perfusion system was able to deliver vascular contrast agent to the vessels of the lamina. The individual secondary lamellae (average length 0.142 mm) could not be seen in detail, although differentiation between primary and secondary lamellae was achieved. This approaches, but does not yet reach, the current gold standard, histology, for assessment of the lamellae; however, with further refinement of this imaging technique, improved resolution may be accomplished in future studies.

Funder

Australian Synchrotron

Publisher

International Union of Crystallography (IUCr)

Subject

Instrumentation,Nuclear and High Energy Physics,Radiation

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3