CT dosimetry at the Australian Synchrotron for 25–100 keV photons and 35–160 mm-diameter biological specimens

Author:

Midgley Stewart,Schleich Nanette,Merchant Alex,Stevenson Andrew

Abstract

The dose length product (DLP) method for medical computed tomography (CT) dosimetry is applied on the Australian Synchrotron Imaging and Medical Beamline (IMBL). Beam quality is assessed from copper transmission measurements using image receptors, finding near 100% (20 keV), 3.3% (25 keV) and 0.5% (30–40 keV) relative contributions from third-harmonic radiation. The flat-panel-array medical image receptor is found to have a non-linear dose response curve. The amount of radiation delivered during an axial CT scan is measured as the dose in air alone, and inside cylindrical PMMA phantoms with diameters 35–160 mm for mono-energetic radiation 25–100 keV. The radiation output rate for the IMBL is comparable with that used for medical CT. Results are presented as the ratios of CT dose indices (CTDI) inside phantoms to in air with no phantom. Ratios are compared for the IMBL against medical CT where bow-tie filters shape the beam profile to reduce the absorbed dose to surface organs. CTDI ratios scale measurements in air to estimate the volumetric CTDI representing the average dose per unit length, and the dose length product representing the absorbed dose to the scanned volume. Medical CT dose calculators use the DLP, beam quality, axial collimation and helical pitch to estimate organ doses and the effective dose. The effective dose per unit DLP for medical CT is presented as a function of body region, beam energy and sample sizes from neonate to adult.

Funder

University of Otago

Australian Synchrotron

Publisher

International Union of Crystallography (IUCr)

Subject

Instrumentation,Nuclear and High Energy Physics,Radiation

Reference51 articles.

1. ARPANSA. (2005). Code of practice for the exposure of humans to ionising radiation for research purposes. Report RPS8. Australian Radiation Protection and Nuclear Science Agency, Miranda, New South Wales, Australia.

2. ARPANSA. (2011). Australian national diagnostic reference levels for MDCT - Adult. Report. Australian Radiation Protection and Nuclear Science Agency, Miranda, New South Wales, Australia.

3. ARPANSA. (2012). Australian national diagnostic reference levels for MDCT - Paediatric. Report. Australian Radiation Protection and Nuclear Science Agency, Miranda, New South Wales, Australia.

4. Attwood, D. (2000). Soft X-rays and Extreme Ultraviolet Radiation. Cambridge University Press.

5. Measuring the linearity of X-ray detectors: consequences for absolute attenuation, scattering and absolute Bragg intensities

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Characterization of selected additive manufacturing materials for synchrotron monochromatic imaging and broad-beam radiotherapy at the Australian synchrotron-imaging and medical beamline;Physics in Medicine & Biology;2024-05-30

2. Efficacy of MOSkins in BreastCT Dosimetry;2023 IEEE Nuclear Science Symposium, Medical Imaging Conference and International Symposium on Room-Temperature Semiconductor Detectors (NSS MIC RTSD);2023-11-04

3. In-situ x-ray fluorescence imaging of the endogenous iodine distribution in murine thyroids;Scientific Reports;2022-02-21