Advancements towards the implementation of clinical phase-contrast breast computed tomography at Elettra
-
Published:2019-06-14
Issue:4
Volume:26
Page:1343-1353
-
ISSN:1600-5775
-
Container-title:Journal of Synchrotron Radiation
-
language:
-
Short-container-title:J Synchrotron Radiat
Author:
Longo Renata, Arfelli Fulvia, Bonazza Deborah, Bottigli Ubaldo, Brombal LucaORCID, Contillo Adriano, Cova Maria A., Delogu Pasquale, Di Lillo Francesca, Di Trapani Vittorio, Donato Sandro, Dreossi Diego, Fanti Viviana, Fedon Christian, Golosio Bruno, Mettivier Giovanni, Oliva Piernicola, Pacilè Serena, Sarno Antonio, Rigon Luigi, Russo Paolo, Taibi Angelo, Tonutti Maura, Zanconati Fabrizio, Tromba Giuliana
Abstract
Breast computed tomography (BCT) is an emerging application of X-ray tomography in radiological practice. A few clinical prototypes are under evaluation in hospitals and new systems are under development aiming at improving spatial and contrast resolution and reducing delivered dose. At the same time, synchrotron-radiation phase-contrast mammography has been demonstrated to offer substantial advantages when compared with conventional mammography. At Elettra, the Italian synchrotron radiation facility, a clinical program of phase-contrast BCT based on the free-space propagation approach is under development. In this paper, full-volume breast samples imaged with a beam energy of 32 keV delivering a mean glandular dose of 5 mGy are presented. The whole acquisition setup mimics a clinical study in order to evaluate its feasibility in terms of acquisition time and image quality. Acquisitions are performed using a high-resolution CdTe photon-counting detector and the projection data are processed via a phase-retrieval algorithm. Tomographic reconstructions are compared with conventional mammographic images acquired prior to surgery and with histologic examinations. Results indicate that BCT with monochromatic beam and free-space propagation phase-contrast imaging provide relevant three-dimensional insights of breast morphology at clinically acceptable doses and scan times.
Publisher
International Union of Crystallography (IUCr)
Subject
Instrumentation,Nuclear and High Energy Physics,Radiation
Reference66 articles.
1. AB-CT. (2019). Advanced Breast-CT, https://www.ab-ct.com/nuview/. 2. Ballabriga, R., Alozy, J., Campbell, M., Frojdh, E., Heijne, E., Koenig, T., Llopart, X., Marchal, J., Pennicard, D., Poikela, T., Tlustos, L., Valerio, P., Wong, W. & Zuber, M. (2016). J. Instrum. 11, P01007. 3. Optimization of propagation-based x-ray phase-contrast tomography for breast cancer imaging 4. Chromatic X-ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC 5. Berger, N., Marcon, M., Saltybaeva, N., Kalender, W. A., Alkadhi, H., Frauenfelder, T. & Boss, A. (2019). Invest. Radiol. doi:10.1097/RLI.0000000000000552.
Cited by
53 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|