Considerations for three-dimensional image reconstruction from experimental data in coherent diffractive imaging

Author:

Lundholm Ida V.,Sellberg Jonas A.,Ekeberg Tomas,Hantke Max F.,Okamoto Kenta,van der Schot Gijs,Andreasson Jakob,Barty Anton,Bielecki Johan,Bruza Petr,Bucher Max,Carron Sebastian,Daurer Benedikt J.,Ferguson Ken,Hasse Dirk,Krzywinski Jacek,Larsson Daniel S. D.,Morgan Andrew,Mühlig Kerstin,Müller Maria,Nettelblad Carl,Pietrini Alberto,Reddy Hemanth K. N.,Rupp Daniela,Sauppe Mario,Seibert Marvin,Svenda Martin,Swiggers Michelle,Timneanu Nicusor,Ulmer Anatoli,Westphal Daniel,Williams Garth,Zani Alessandro,Faigel Gyula,Chapman Henry N.,Möller Thomas,Bostedt Christoph,Hajdu Janos,Gorkhover Tais,Maia Filipe R. N. C.

Abstract

Diffraction before destruction using X-ray free-electron lasers (XFELs) has the potential to determine radiation-damage-free structures without the need for crystallization. This article presents the three-dimensional reconstruction of the Melbournevirus from single-particle X-ray diffraction patterns collected at the LINAC Coherent Light Source (LCLS) as well as reconstructions from simulated data exploring the consequences of different kinds of experimental sources of noise. The reconstruction from experimental data suffers from a strong artifact in the center of the particle. This could be reproduced with simulated data by adding experimental background to the diffraction patterns. In those simulations, the relative density of the artifact increases linearly with background strength. This suggests that the artifact originates from the Fourier transform of the relatively flat background, concentrating all power in a central feature of limited extent. We support these findings by significantly reducing the artifact through background removal before the phase-retrieval step. Large amounts of blurring in the diffraction patterns were also found to introduce diffuse artifacts, which could easily be mistaken as biologically relevant features. Other sources of noise such as sample heterogeneity and variation of pulse energy did not significantly degrade the quality of the reconstructions. Larger data volumes, made possible by the recent inauguration of high repetition-rate XFELs, allow for increased signal-to-background ratio and provide a way to minimize these artifacts. The anticipated development of three-dimensional Fourier-volume-assembly algorithms which are background aware is an alternative and complementary solution, which maximizes the use of data.

Funder

Vetenskapsrådet

Knut och Alice Wallenbergs Stiftelse

European Research Council

Stiftelsen för Strategisk Forskning

Swedish Foundation for International Cooperation in Research and Higher Education

Ministerstvo Školství, Mládeže a Tělovýchovy

Nanoscience and Nanotechnology Area of Advance, Chalmers Tekniska Högskola

European Regional Development Fund

Nemzeti Kutatási, Fejlesztési és Innovációs Hivatal

U.S. Department of Energy, Office of Science

Publisher

International Union of Crystallography (IUCr)

Subject

Condensed Matter Physics,General Materials Science,Biochemistry,General Chemistry

Cited by 42 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3