Abstract
Sufficiently high completeness of diffraction data is necessary to correctly determine the space group, observe solid-state structural transformations or investigate charge density distribution under pressure. Regrettably, experiments performed at high pressure in a diamond anvil cell (DAC) yield inherently incomplete datasets. The present work systematizes the combined influence of radiation wavelength, DAC opening angle and sample orientation in a DAC on the completeness of diffraction data collected in a single-crystal high-pressure (HP) experiment with the help of dedicated software. In particular, the impact of the sample orientation on the achievable data completeness is quantified and proved to be substantial. Graphical guides for estimating the most beneficial sample orientation depending on the sample Laue class and assuming a few commonly used experimental setups are proposed. The usefulness of these guides has been tested in the case of luminescent 1,3-diacetylpyrene, suspected to undergo transitions from the α phase (Pnma) to the γ phase (Pn21
a) and δ phase (P1121/a) under pressure. Effective sample orientation has ensured over 90% coverage even for the monoclinic system and enabled unrestrained structure refinements and access to complete systematic extinction patterns.
Publisher
International Union of Crystallography (IUCr)
Subject
Condensed Matter Physics,General Materials Science,Biochemistry,General Chemistry
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献