Author:
Janjatovic Petar,Balos Sebastian,Radisavljevic Igor,Dramicanin Miroslav,Cekic Olivera Eric,Sidjanin L.
Abstract
In this study, the performance of austempered compacted graphite iron was evaluated to find its suitability as perforated plates used in add-on armour. Perforated compacted graphite plates were subjected to austenitisation at 900 °C for 2 h followed by austempering at 275 and 400 °C for 1 h. The basic plate was fixed at 400 mm away from the perforated plate and armour and then piercing incendiary projectile was shot from a distance of 100 m. It was observed that both 7 mm and 9 mm perforated plates austempered at lower temperature of 275 °C producing higher hardness and lower ductility were effective in fracturing the penetrating core, thereby significantly decreasing the chances of penetrating the basic plate.
Publisher
Defence Scientific Information and Documentation Centre
Subject
Electrical and Electronic Engineering,Computer Science Applications,General Physics and Astronomy,Mechanical Engineering,Biomedical Engineering,General Chemical Engineering
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献