Abstract

Motion management strategies are important during stereotactic ablative body radiotherapy for abdominal targets. The kidney is a mobile retroperitoneal organ that moves with respiration. A review of the literature was performed to investigate the reported degree of kidney motion associated with various breathing conditions. A structured search was performed using Medline from January 1970 to May 2013 for all publications describing cranial-caudal kidney motion. Relevance to radiotherapy practice was reviewed based on any breathing instructions and/or immobilization equipment that could affect breathing pattern. Studies were categorized under three types of breathing conditions: Forced-shallow, breath-hold/deep and free. A total of 25 publications were identified describing cranial-caudal kidney motion with a combined total of 415 participants. Three publications described forced-shallow breathing using prone positioning or abdominal compression plates. Prone positioning, compared to supine positioning, did little to minimise kidney motion, however use of compression plates can result in kidney motion of less than 5 mm. Eight publications described deep breathing/breath hold techniques that showed average kidney motion ranging between 10 mm-40 mm. Fifteen publications investigated kidney motion under free breathing with the majority reporting mean motion of less than 10 mm. Kidney movement of up to 8.1 mm in the anterior posterior direction and 6.2 mm laterally were reported with no indications that breathing technique can influence the extent of this motion. In summary, kidney movement is complex and consideration should be made to ensure that motion management strategies provide the desired radiotherapy benefit. There are limited publications on the effectiveness of abdominal compression on reducing kidney motion which warrant further investigation in this area.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

Cited by 37 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3