Protons Safely Allow Coverage of High-Risk Nodes for Patients with Regionally Advanced Non-Small-Cell Lung Cancer

Author:

Nichols R. C.1,Huh S. H.1,Hoppe B. S.1,Henderson R. H.1,Li Z.1,Flampouri S.1,D'Agostino H. J.2,Cury J. D.3,Pham D. C.4,Mendenhall N. P.1

Affiliation:

1. University of Florida, Proton Therapy Institute, Jacksonville, FL, USA

2. University of Florida, Department of Surgery and Internal Medicine, Jacksonville, FL, USA

3. University of Florida, Department of Pulmonary Medicine, Jacksonville, FL, USA

4. University of Florida, Division of Medical Oncology, Jacksonville, FL, USA

Abstract

Our objective was to determine if protons allow for the expansion of treatment volumes to cover high-risk nodes in patients with regionally advanced non-small-cell lung cancer. In this study, 5 consecutive patients underwent external-beam radiotherapy treatment planning. Four treatment plans were generated for each patient: 1) photons (x-rays) to treat positron emission tomography (PET)-positive gross disease only to 74 Gy (XG); 2) photons (x-rays) to treat high-risk nodes to 44 Gy and PET-positive gross disease to 74 Gy (XNG); 3) protons to treat PET-positive gross disease only to 74 cobalt gray equivalent (PG); and 4) protons to treat high-risk nodes to 44 CGE and PET-positive gross disease to 74 CGE (PNG). We defined high-risk nodes as mediastinal, hilar, and supraclavicular lymph nodal stations anatomically adjacent to the foci of PET-positive gross disease. Four-dimensional computed tomography was utilized for all patients to account for tumor motion. Standard normal-tissue constraints were utilized. Our results showed that proton plans for all patients were isoeffective with the corresponding photon (x-ray) plans in that they achieved the desired target doses while respecting normal-tissue constraints. In spite of the larger volumes covered, median volume of normal lung receiving 10 CGE or greater (V10Gy/CGE), median V20Gy/CGE, and mean lung dose were lower in the proton plans (PNG) targeting gross disease and nodes when compared with the photon (x-ray) plans (XG) treating gross disease alone. In conclusion, proton plans demonstrated the potential to safely include high-risk nodes without increasing the volume of normal lung irradiated when compared to photon (x-ray) plans, which only targeted gross disease.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3