Simultaneous Integrated Boost in Breast Conserving Radiotherapy: Is Replanning Necessary following Tumor Bed Change?

Author:

Yang ZhaoZhi1,Chen JiaYi1,Xie Jiang1,Zhu ChuanYing1,Pan ZiQiang1,Yu XiaoLi1,Mei Xin1,Fu XiaoLong1,Guo XiaoMao1

Affiliation:

1. Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, China

Abstract

Tumor bed (TB) change is often seen during the whole breast irradiation (WBI) in early breast cancer patients. The aims of this study were to evaluate change in seroma volume on repeat CTs and to explore whether replanning is necessary in breast conserving radiotherapy (RT) using the intensity modulated radiotherapy (IMRT) with simultaneous integrated boost (SIB). Thirty patients underwent WBI with 84 CT scans (24 with 3 CTs (CT1, CT2 and CT3) and 6 without CT3) during the 6 weeks of RT were reviewed. TB and other target volumes on all CTs were delineated and compared. IMRT-SIB treatment plans with 50.68 Gy to the whole breast and 64.4 Gy to the boost in 28 fractions were constructed in the CT1. Replan and hybrid plan (without replanning) in the CT2 were reproduced. Dosimetric differences between the replans and hybrid plans were also compared. The mean TB volumes for CT1, CT2 and CT3 were 42.1 cm3, 20.1 cm3, 17.0 cm3, respectively. The mean TB volume reduction was 40.5% from the CT1 to CT2 and 4.3% from the CT2 to CT3. The difference of TB volumes between the CT1 and CT2 was statistically significance ( p < 0.001), but not significant between the CT2 and CT3 ( p = 1.000). For all patients, target coverage remained adequate with either hybrid plans or replans. However, replanning can significantly decrease the whole breast mean dose (35.2 vs. 35.6 Gy, p = 0.026) and breast volume outside the boost receiving 95% of the boost prescribed dose (39.5 vs. 68.2 cm3, p < 0.001). In summary, boost volume could irradiate adequately after the significance shrinkage of tumor bed with the fractionated schedule of IMRT-SIB, but replanning on a second CT could avoid the undesired high dose irradiated breast_tissue outside boost.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3