Dosimetric Evaluation of Volumetric-Modulated Arc Therapy (RapidArc) for Primary Leiomyosarcoma in the Spine

Author:

Wu Yong-Zhong1,Jin Fu2,Wang Ying1,Zhou Juan3,Wu Li-Hua2,He Guang-Lei2,Qiu Da2,He Ya-Nan2,Liu Xian-Feng2,Zhong Ming-Song2

Affiliation:

1. Department of Radiation Oncology, Chongqing Cancer Institute, Chongqing, 400030, People's Republic of China

2. Physics Unit, Chongqing Cancer Institute, Chongqing, 400030, People's Republic of China

3. Department of Criminal Investigation, Southwest University of Political Science and Law, Chongqing, 401120, People's Republic of China

Abstract

This study aims to investigate the suitability of volumetric-modulated arc therapy (VMAT) with RapidArc for primary leiomyosarcoma (LMS) in the spine, and present a new method to improve the target coverage and organs at risk (OAR) sparing. Five patients with LMS were retrospectively reviewed. The intensity-modulated radiotherapy (IMRT) with five coplanar beams (5b-IMRT) or seven coplanar beams (7b-IMRT), and VMAT using four quasi-quarter coplanar arcs (4q-VMAT) or two full coplanar arcs (2f-VMAT) were generated. Planning target volume (PTV) dose coverage, OAR dose sparing, conformity index (CI), and homogeneity index (HI) were evaluated. A hollow-cylinder model (HCM) was also used for feasible optimal beam arrangements. The mean doses to PTV were 95.2% ± 1.0%, 93.0% ± 1.0%, 97.9% ± 1.0% and 96.2% ± 1.5% for 4q-VMAT, 2f-VMAT, 5b-IMRT and 7b-IMRT respectively, while the mean maximum doses to spinal cord (SC) were 43.7 ± 0.9 Gy, 42.0 ± 0.8 Gy, 41.4 ± 1.2 Gy and 40.6 ± 1.4 Gy. Compared to 5b-IMRT, the mean doses delivered to kidneys decreased by about 35.1% (8.5 Gy), 2.5% (0.6 Gy) and 35.5% (8.6 Gy) for 4q-VMAT, 2f-VMAT, and 7b-IMRT, respectively. The CI proposed by Baltas et al. was twice as good with IMRT than with 4q-VMAT, and the numbers of monitor units were increased five- and threefold with 7b-IMRT and with 5b-IMRT compared to VMAT. The unexpected results we presented here show that VMAT technique can't achieve highly conformal treatment plans while maintaining SC sparing for LMS in the spine. An approach is proposed based on a hollow-cylinder model, but it is difficult to apply to clinical practice. In this case, VMAT is not superior to IMRT except for significant reduction in delivery time.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3