A Study of the Anatomic Changes and Dosimetric Consequences in Adaptive CRT of Non-Small-Cell Lung Cancer Using Deformable CT and CBCT Image Registration

Author:

Ma Changsheng1,Hou Yong1,Li Hongsheng1,Li Dengwang2,Zhang Yingjie1,Chen Siye1,Yin Yong1

Affiliation:

1. Shandong Provincial Key Laboratory of Radiation Oncology, Department of Radiation Oncology, Shandong Academy of Medical Sciences, Shandong Tumor Hospital, No. 440 Jiyan Road, 250117 Jinan, China

2. Shandong Normal University, No. 88 Wenhua East Road, 250014 Jinan, China

Abstract

The aim of this study is to evaluate anatomic lung tumor changes and dosimetric consequences utilizing the deformable daily kilovolt (KV) cone-beam computer tomography (CBCT) image registration. Five patients diagnosed with NSCLC were treated with three-dimensional conformal radiotherapy (3D CRT) and 10 daily KV CBCT image sets were acquired for each patient. Each CBCT image and plan CT were imported into the deformable image registration (DIR) system. The plan CT image was deformed by the DIR system and a new contour on CBCT was obtained by using the auto-contouring function of the DIR. These contours were individually marked as CBCT f1, CBCT f2,…, and CBCT f10, and imported into a treatment planning system (TPS). The daily CBCT plan was individually generated with the same planning criteria based on new contours. These plans were individually marked as CBCTp1, CBCTp2,…, and CBCTp10, followed by generating a dose accumulation plan (DA plan) in original pCT image contour sets by adding all CBCT plans using Varian Eclipse TPS. The maximum, minimum and mean doses to the plan target volume (PTV) in the 5 DA plans were the same with the CT plans. However, the volume of radiation 5, 10, 20, 30, and 50 Gy of the total lungs in DA plans were less than those of the CT plans. The maximum dose of the spinal cord in the DA plans were average 27.96% less than the CT plans. The mean dose for the left, right, and total lungs in the DA plans were reduced by 13.80%, 23.65%, and 12.96%, respectively. The adaptive 3D CRT based on the deformable registration can reduce the dose to the lung and the spinal cord with the same PTV dose coverage. Moreover, it provides a method for further adaptive radiotherapy exploration.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3