The Dosimetric and Delivery Advantages of a New 160-leaf MLC

Author:

Prah D. E.1,Kainz K.1,Peng C.1,Li X. A.1

Affiliation:

1. Department of Radiation Oncology, Medical College of Wisconsin, 8701 Watertown Plank Road, Milwaukee, WI 53226, USA

Abstract

The purpose of this study was to conduct a measurement and treatment planning study on the dosimetric and delivery advantages of a new 160-leaf multileaf collimator (MLC). Recently, a new 160-leaf multileaf collimator (Siemens 160 MLC™) was introduced. The 160-MLC is a single focused design that consists of 160-leafs (80 pairs), each 95 mm thick with a projected leaf width of 5 mm at the machine isocenter. Compared to its double focused predecessors, the 82-leaf MLC (Siemens OPTIVIEW™ MLC) and 58-leaf MLC (Siemens 3-D MLC™), the 160-MLC has leaf widths of half the size. The most notable difference is the new slanted leaf design that replaced the tongue and groove system and allows for complete interdigitation. A systematic study that compared the dosimetric and delivery differences among the 160-MLC, 58-MLC, and divergent Cerrobend blocks was performed. Dosimetric conformity for each collimator type was determined by conforming each to circular targets of various diameters. The effective penumbra for each collimator type was calculated by conforming each, at various collimator angles, to a square stationary target. The quality of 3D conformal radiotherapy treatment (3D-CRT) plans and the quality intensity modulated radiation treatment (IMRT) plans were respectively compared with each collimator type. The 160-MLC was found to have improved dosimetric conformity over the 58-MLC. The divergent Cerrobend block showed marginal dosimetric conformity improvement over the 160-LMC. Overall, the 160-MLC had a 45% and 29% reduction in the 20/80 and 30/90 effective penumbra over the 58-MLC, respectively, while exhibiting only a slightly larger effective penumbra over the divergent Cerrobend block. Comparing 3D-CRT plans generated for small lesions of the head and neck, the V100 for the PTV of the plans generated with the Cerrobend blocks, the 58-MLC, and the 160-MLC were 97.78%, 92.51%, and 99.18%, respectively, while with regards to the OARs, the three produced similar DVHs. IMRT plans generated with the 160-MLC were found to significantly reduce the total delivered monitor units by up to 14.7% and the number of segments by as much as 10.7% compared to the 58-MLC. The average delivery time for the direct aperture optimized (DAO) IMRT plans generated with the 160-MLC was approximately 5 minutes. Overall, compared to the 58-MLC, the new 160-MLC was found to improve dosimetric conformity and IMRT delivery efficiency.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3