ITO ELECTRODES MODIFIED WITH MnO2/SiO2 FOR THE DETERMINATION OF HYDROGEN PEROXIDE

Author:

Kovalyk A.1,Tananaiko O.1

Affiliation:

1. Taras Shevchenko National University of Kyiv

Abstract

Nanostructured transition metal oxide nanoparticles possess a catalytic activity to hydrogen peroxide. Manganese dioxide particles are one of the promising and available modificators of the electrode surface. Nanostructured MnO2 deposited onto the surface of the electrode enhances the electron transport from the H2O2 molecule to the surface. Thus selectivity and sensitivity of H2O2 detection can be improved. There are a lot of different methods of the impregnation of manganese dioxide particles onto electrode surface. An electrophoretic deposition is one of the most simple and rapid. By adjusting the electrodeposition parameters, particles of different sizes or films can be obtained. A simple and novel hydrogen peroxide sensor based on layer-by-layer assembly of MnO2 nanoparticles and SiO2 film on the ITO electrode was developed. For this purpose MnO2 nanoparticles were electrodeposited on the surface of ITO electrode from MnSO4/CH3COOK solution. The electrochemical characteristics of the modified electrodes were investigated by cyclic voltammetry.The presence of MnO2 on the surface of modified electrode was indicated by the appearance of clear oxidation-reduction peaks of Mn(IV)/Mn(III,II) at E=0.65 V in the electrolyte solution in contrast to unmodified electrode. Optimization of measurement parameters such as the amount of MnO2, applied potential and pH value were studied in details. Under the optimum conditions, the calibration curve for H2O2 determination using modified electrode was linear in the range from 1×10−4 to 1×10−3 mol/dm3 with a detection limit of 0.09×10−4 mol/dm3 (S/N = 3). The linear rang for non-modified electrode was from 1×10−3 to 1×10−2 mol/dm3 with a detection limit of 1.8×10−4 mol/dm3 (S/N = 3). The modified ITO electrode was characterized by higher current than non modified ITO as a result of increasing of electroactive surface area and catalytic effect of electrodeposited MnO2.For the stabilization of MnO2 particles and protection of the electrode surface from impurities, the ITO/MnO2 was covered by thin silica film. The selectivity of H2O2 determination at ITO modified with MnO2/SiO2 was better than at ITO especially in the presence of ascorbic acid which is oxidized at the same potential as H2O2. The oxidation current of ascorbic acid was much higher than H2O2 at nonmodified ITO in contrast to ITO modified with MnO2/SiO2. The developed ITO electrode modified with MnO2/SiO2 is a perspective element of amperometric sensor for the detection of hydrogen peroxide.

Publisher

Taras Shevchenko National University of Kyiv

Subject

Pharmacology (medical),Complementary and alternative medicine,Pharmaceutical Science

Reference15 articles.

1. 1. Rax V.A., Esaulenko A.M. Modern Chromatography on the Crust of theWaves of Progress. Tutorial. Kyiv: Avanpost, 2014, 168 р. (In Ukrainian).

2. 2. Zherebtsov N.A., Popova T.N., Artyukhov V.G. Biochemistry. Voronezh: Publishing house of Voronezh State University, 2002, 265-285 р. (In Russian).

3. 3. Katral R.V., Chemical sensors. Moscow: Nauchnyj mir, 2000, 144 p. (In Russian).

4. 4. Biosensors: basics and applications. Ed. Turner E., Karube I., Wilson J., Moscow: Mir, 1992, 614 p. (In Russian) Modereggera H., Švancarab I., Vytˇrasb K., Kalcher K., Talanta, 2004, 64, 1151–1159.

5. 6. Chunyan Guo, Hua Li, Xuan Zhang, Huanhuan Huo, Cailing Xu., Sens. Actuators B, 2015, 206, 407–414.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3