Results of biosimilar assessing of insulin aspart preparations of Russian and foreign production using the hyperinsulinemic euglycemic clamp method and studying the use of a new ultra-fast-acting Russian biosimilar in pumps

Author:

Saverskaya E. N.1ORCID,Koksharova E. O.2ORCID,Noskov S. M.3ORCID,Zaikin P. G.4ORCID,Banko V. V.4ORCID,Arefeva A.  N.4ORCID

Affiliation:

1. Russian Biotechnological University (ROSBIOTECH)

2. National Medical Research Center for Endocrinology

3. Clinical Hospital No. 3

4. Farm-Holding CJSC

Abstract

Introduction. Ultra-fast-acting insulin aspart has great potential for improving postprandial glycemia in patients with type 1 and type 2 diabetes mellitus due to its pharmacological characteristics. The development and production of biosimilars are increasing the availability of modern insulins for patients.Aim. To evaluate the comparability of the pharmacokinetics and pharmacodynamics profiles of insulin aspart GP40311 (tested biosimilar of domestic production) and the reference drug (produced in Denmark) under conditions of a hyperinsulinemic euglycemic clamp in healthy volunteers. To evaluate the stability of a new ultrafast-acting biosimilar when used for continuous subcutaneous infusion in insulin pumps.Materials and methods. Double-blind, randomized, crossover study assessing the pharmacokinetics, pharmacodynamics and safety of the tested biosimilar GP40311 of domestic production and the reference drug produced in Denmark, in the form of a solution for intravenous and subcutaneous administration of 100 IU/ml, the study was conducted under conditions of a hyperinsulinemic euglycemic clamp with the participation of 36 healthy volunteers. A study of the stability, dosing accuracy and tendency to catheter occlusion of a domestic drug for continuous subcutaneous infusion was carried out using several types of insulin pumps using the gravimetric method for 72 hours. Dosing accuracy was determined at the minimum and maximum bolus dose, stability was assessed by pH and quantitative insulin content aspart. The quantitative content of insulin and impurities was assessed by high-performance liquid chromatography.Results and discission. The 90% confidence interval for the ratio of geometric mean values of the main parameters of pharmacokinetics (AUCins.0-t and Cins.max) of insulin aspart test and reference drugs corresponded to the acceptable values of 80.00– 125.00%, which indicated their biosimilarity. When assessing PD, the comparability of action parameters is shown. The safety of the study drugs is comparable. Domestic insulin aspart met the specification standards when used for continuous subcutaneous infusion according to physicochemical parameters: pH, quantitative determination of insulin aspart, impurity content. The accuracy of dosing and the absence of occlusions in systems for 72 hours when using the drug in pumps have been established.Conclusion. The study drugs were found to be biosimilar and equally safe. Domestic insulin aspart meets specification standards and can be used in various types of pumps.

Publisher

Remedium, Ltd.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3