Comparison Of Sagittal Condylar Angle Obtained Using Cone Beam Computed Tomography And Interocclusal Record Materials- An In Vivo Study

Author:

Bahadursingh Ailsinghani Sneha,Vikhe Deepak,Palekar Umesh,Saraf Veena,Hajira Neha,Madanshetty Pallavi

Abstract

: The sagittal condylar guidance angle (SCCA) is calculated by the condyle and articular disc traversing the contour of the glenoid fossa and the articular eminence. The condylar path is controlled by the shape of the fossa, the attachments of the ligaments, the biting load during movement (muscular influence), and the amount of protrusion. The SCGA on an articulator is determined using protrusive records of the patient. Intraoral registrations may compromise accuracy because of dimensional instability of registration materials and it becomes difficult for the dentist to select an appropriate material. The use of cone beam computed tomography (CBCT) has recently become much more common, and when measuring the SCGA using CBCT, more reliable results can be expected. This study was designed to compare the SCGA obtained using CBCT and protrusive interocclusal record made using polyvinyl siloxane and aluwax. Thirty dentulous subjects were selected. SCGA was calculated using CBCT scans for each subject. Intraoral protrusive records were made using polyvinyl siloxane and aluwax bite registration materials at 6mm of protrusion. Records were used to program the articulator and variation in the SCCA was noted. No significant difference was observed between right and left mean values of SCGA in CBCT, polyvinyl siloxane and aluwax. Positive correlation was found between all the three groups; however, significant difference was found in the mean values of SCGA between CBCT and polyvinyl siloxane, CBCT and aluwax (P=0.0001). No significant difference was found in the mean values of SCGA between polyvinyl siloxane and aluwax (P=0.9254). CBCT gave higher mean SCGA values than those obtained using polyvinyl siloxane and aluwax on semi-adjustable articulator in dentulous subjects; whereas mean SCGA values were comparable between polyvinyl siloxane and aluwax. The right and left SCGA values were comparable in each method.

Publisher

International Journal of Pharma and Bio Sciences

Subject

General Earth and Planetary Sciences,General Environmental Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3