Bioanalytical Method Development and Validation of Selinexor in Rat Plasma by Liquid Chromatography-Tandem Mass Spectrometry

Author:

Yaswanth MurthaetiORCID,Sreekanth M,Valli Syed Sadaq,Narayana D Venkata,Sreedhar V,Venkataramana Kanuma,Pravallika K E

Abstract

A simple, rapid, precise, sensitive, and reproducible reverse-phase high-performance liquid chromatography (RPHPLC) LCMS/MS method has been developed for the bioanalytical method for Selinexor with D6-Selinexor as Internal Standard in the pharmaceutical dosage form. Chromatographic separation of Selinexor was achieved on Waters Alliance-e2695, by using X-Bridge phenyl, 150x4.6mm, 3.5μm column, and the mobile phase containing 0.1% Formic acid & Acetonitrile in the ratio of 80:20% v/v. The flow rate was 1.0 ml/min; detection was carried out by absorption at 225nm using a photodiode array detector at ambient temperature. The method was validated to fulfill International Conference on Harmonization (ICH) requirements and this validation included specificity, selectivity, matrix effect, linearity, the limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy. The proposed method was Bio-analytical validated according to USFDA guidelines. This method was found to be a very simple, economical, suitable, precise, accurate, and stable method for pharmacokinetic analysis of Selinexor and study of its stability. The calibration curve was linear over the concentration range from 0 to 40 ng/ml, and the lower limit of detection of 12.5 ng/ml. The accuracy and precision of the method were within the acceptable limit of ±20% at the lower limit of quantitation and ±15% at other concentrations. Selinexor was unstable at room temperature it showed more than 25% loss after 24 h. While, Selinexor is very stable at refrigerator 40C auto-sampler, freeze/thaw cycles, and 30 days storage in a freezer at 35 ± 20C. All results were acceptable and this confirmed that the method is suitable for its intended use in routine quality control and an assay of drugs.

Publisher

International Journal of Pharma and Bio Sciences

Subject

General Earth and Planetary Sciences,General Environmental Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3