Comparison of Diagnostic Accuracy of Cone Beam Computed Tomography(CBCT) and Digital Radiography Measurements as an Aid in the Placements of Dental Implants: A Retrospective Stud

Author:

Shetty ShreyaORCID,Alwaznah Jana Ahmad,Abdou Jumana Thaer,Algohani Llojun Khaled,Otiaf Renad Hassan,Shaikh Khammarunissa

Abstract

Cone beam computed tomography (CBCT) has gained wide popularity among dentists. This can be attributed to its ability to provide bone morphology, bone dimension details and vital structure locations by producing cross-sectional images along the arches. However, one of the reasons routine usage is hampered is its high cost. It would be a great benefit to the practice of dental implants if there was a more economical alternative. Anatomic landmarks in both the maxilla and the mandible are important to be considered during implant placement, and if overlooked, may lead to failures and complications and this is where Cone beam computed tomography (CBCT) has a slight edge over its other diagnostic counterparts. However, newer digital radiographs have been found to be economical and fairly accurate in line with the highly sophisticated CT scans. Therefore, this study aimed to compare and assess the diagnostic accuracy of CBCT and digital radiography (vistascan) in the placement of implants, which may provide an aid in terms of providing an accurate implant size during the surgical procedure for successful dental implant placement. Data was collected from CBCT and vistascan image measurements made pre-operatively prior to implant placement. The measurements were then compared using certain anatomical landmarks as reference in the maxillary and mandibular arches and additionally, with the actual size of implant placed post-operatively. Statistical analysis using SPSS V22 and paired ‘t’ tests and ANOVA revealed no significant differences in the measurements between both the images. (P>0.05). Additionally, both the image measurements were very close to the actual size of the implant placed. Since both imaging techniques were similar in terms of accuracy for implant placement, use of digital radiography (vistascan) may be encouraged as a cost effective option as against CBCT which is expensive for routine assessment. 

Publisher

International Journal of Pharma and Bio Sciences

Subject

General Earth and Planetary Sciences,General Environmental Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3