Computed Tomography-Based Feasibility Study of C1 Posterior Arch Crisscrossing Screw Fixation

Author:

Sangondimath Gururaj,Mallepally Abhinandan Reddy,Salimath Suman

Abstract

Study Design: Retrospective radiographic analysis.Purpose: Posterior fixation of C1 using screws is the most popular technique among the various methods for C1 stabilization, but it places the surrounding neurovascular structures at risk. Approximately 20% of the population has an anomalous groove for the vertebral artery; therefore, salvage methods are necessary. Therefore, we analyzed the feasibility of a newer C1 posterior arch crisscrossing screw fixation technique and studied its feasibility in the Indian population on the basis of the anatomy of the C1 posterior arch.Overview of Literature: Multiple techniques have been described for C1–C2 fixation, such as wiring techniques, interlaminar clamps, transarticular screws, screw-plate/screw-rod system fixation, and hook-screw system fixation techniques, to provide rigid C1–C2 stability. However, although C1 fixation has evolved with time, it is not complication-free.Methods: A 100 computed tomography (CT) scans of cervical spines with 1 mm slice thickness in the axial and sagittal sections obtained were randomly selected for the evaluation. Atlantoaxial anomalies due to trauma, deformities, infections, and tumors were excluded. All the images were measured for height of the posterior tubercle, width of the posterior arch, and length of the screw, and the screw projection angle was calculated. Demographic data were collected for all the subjects.Results: Out of the 88 CT scans analyzed, the mean height of the posterior tubercle was 7.4 mm, wherein 84.09% exceeded 7 mm, and the width of the posterior tubercle was 5.4 mm, wherein 88.6% (n=78) had posterior arch width >3.5 mm. A total of 13.6% (n=12) vertebrae were not suitable for screw placement, whereas 75% (n=66) vertebrae could accommodate 3.5×15 mm or longer screws. The screw projection angles ranged from 11.2° to 35° on the right and from 15.6° to 38.2° on the left.Conclusions: C1 posterior arch screw fixation is a feasible and safe method because it poses little risk of injury to the surrounding neurovascular structures.

Publisher

Asian Spine Journal (ASJ)

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3