Validation Study of Rajasekaran’s Kyphosis Classification System: Do We Clearly Understand Single- and Two-Column Deficiencies?

Author:

Shetty Ajoy Prasad,Rajavelu Rajesh,Viswanathan Vibhu Krishnan,Watanabe Kota,Chhabra Harvinder Singh,Kanna Rishi Mukesh,Cheung Jason Pui Yin,Hai Yong,Kwan Mun Keong,Wong Chung Chek,Liu Gabriel,Basu Saumajit,Nene Abhay,Naresh-Babu J.,Garg Bhavuk

Abstract

Study Design: Multicenter validation study.Purpose: To evaluate the inter-rater reliability of Rajasekaran’s kyphosis classification through a multicenter validation study.Overview of Literature: The classification of kyphosis, developed by Rajasekaran, incorporates factors related to curve characteristics, including column deficiency, disc mobility, curve magnitude, and osteotomy requirements. Although the classification offers significant benefits in determining prognosis and management decisions, it has not been subjected to multicenter validation.Methods: A total of 30 sets of images, including plain radiographs, computed tomography scans, and magnetic resonance imaging scans, were randomly selected from our hospital patient database. All patients had undergone deformity correction surgery for kyphosis. Twelve spine surgeons from the Asia-Pacific region (six different countries) independently evaluated and classified the deformity types and proposed their surgical recommendations. This information was then compared with standard deformity classification and surgical recommendations.Results: The kappa coefficients for the classification were as follows: 0.88 for type 1A, 0.78 for type 1B, 0.50 for type 2B, 0.40 for type 3A, 0.63 for type 3B, and 0.86 for type 3C deformities. The overall kappa coefficient for the classification was 0.68. Regarding the repeatability of osteotomy recommendations, kappa values were the highest for Ponte’s (Schwab type 2) osteotomy (kappa 0.8). Kappa values for other osteotomy recommendations were 0.52 for pedicle subtraction/disc-bone osteotomy (Schwab type 3/4), 0.42 for vertebral column resection (VCR, type 5), and 0.30 for multilevel VCRs (type 6).Conclusions: Excellent accuracy was found for types 1A, 1B, and 3C deformities (ends of spectrum). There was more variation among surgeons in differentiating between one-column (types 2A and 2B) and two-column (types 3A and 3B) deficiencies, as surgeons often failed to recognize the radiological signs of posterior column failure. This failure to identify column deficiencies can potentially alter kyphosis management. There was excellent consensus among surgeons in the recommendation of type 2 osteotomy; however, some variation was observed in their choice for other osteotomies.

Funder

Asia Pacific Spine Society

Publisher

Asian Spine Journal (ASJ)

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3