Measurement of Radiotracer Concentration in Brain Gray Matter Using Positron Emission Tomography: MRI-Based Correction for Partial Volume Effects

Author:

Müller-Gärtner Hans W.1,Links Jonathan M.1,Prince Jerry L.2,Bryan R. Nick3,McVeigh Elliot3,Leal Jeffrey P.1,Davatzikos Christos2,Frost J. James14

Affiliation:

1. Department of Radiology, Division of Nuclear Medicine, The Johns Hopkins University School of Medicine, Baltimore, Maryland, U.S.A.

2. Department of Electrical and Computer Engineering, The Johns Hopkins University, Baltimore, Maryland, U.S.A.

3. Department of Radiology, Division of Neuroradiology, The Johns Hopkins University School of Medicine, Baltimore, Maryland, U.S.A.

4. Department of Neuroscience, The Johns Hopkins University School of Medicine, Baltimore, Maryland, U.S.A.

Abstract

Accuracy in in vivo quantitation of brain function with positron emission tomography (PET) has often been limited by partial volume effects. This limitation becomes prominent in studies of aging and degenerative brain diseases where partial volume effects vary with different degrees of atrophy. The present study describes how the actual gray matter (GM) tracer concentration can be estimated using an algorithm that relates the regional fraction of GM to partial volume effects. The regional fraction of GM was determined by magnetic resonance imaging (MRI). The procedure is designated as GM PET. In computer simulations and phantom studies, the GM PET algorithm permitted a 100% recovery of the actual tracer concentration in neocortical GM and hippocampus, irrespective of the GM volume. GM PET was applied in a test case of temporal lobe epilepsy revealing an increase in radiotracer activity in GM that was undetected in the PET image before correction for partial volume effects. In computer simulations, errors in the segmentation of GM and errors in registration of PET and MRI images resulted in less than 15% inaccuracy in the GM PET image. In conclusion, GM PET permits accurate determination of the actual radiotracer concentration in human brain GM in vivo. The method differentiates whether a change in the apparent radiotracer concentration reflects solely an alteration in GM volume or rather a change in radiotracer concentration per unit volume of GM.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Clinical Neurology,Neurology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3