On the Uniqueness of Cerebral Blood Flow Measured by the in vivo Autoradiographic Strategy and Positron Emission Tomography

Author:

Howard Bernard E.1,Ginsberg Myron D.1,Hassel William R.1,Lockwood Alan H.1,Freed Philip1

Affiliation:

1. Positron Emission Tomography Center, University of Miami School of Medicine and Mt. Sinai Medical Center, and Departments of Mathematics and Neurology, University of Miami, Miami, Florida, U.S.A.

Abstract

Factors are examined in this report which govern the uniqueness and sensitivity of regional cerebral blood flow (rCBF), as determined by an in vivo autoradiographic strategy and positron emission tomography (PET), and a series of theorems is derived which specify conditions under which a unique relationship between cumulative cranial activity of the tracer ( C) and regional blood flow ( f) may be assured. It is demonstrated that, independent of the specific form of the arterial tracer input function, flow is a unique function of C whenever the start time ( T1) of the PET scan is coincident with the start of tracer infusion. Other theorems state that, even for nonzero T1s, a unique solution for flow may be expected, as long as the duration of the scan is sufficiently short. The implementation of this theory is illustrated using arterial tracer activity curves obtained in three normal subjects by a multiple arterial sampling procedure following the bolus i. v. infusion of 20–30 μCi of [15O]water. Based on these arterial curves, it is confirmed that the C vs. f relationship resulting from scan parameters T1 = 0 and T2 = 1.5 min (i.e., a PET scan of 90 s commencing with tracer infusion) has an excellent separation of flow values within the range of physiological interest, whereas a 90-s scan beginning at time T1 = 1.7 min results in poorer separation of flow values and loss of the monotonic relationship between C and f at higher flows. The results of this study serve to clarify the in vivo autoradiographic method for measuring rCBF in humans and help to define favorable study parameters for assuring uniqueness and sensitivity of the flow measurement.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Clinical Neurology,Neurology

Cited by 31 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3