Investigation of the hydrodynamic characteristics of an axial flow pump system under special utilization conditions

Author:

Zhang Xiaowen,Tang Fangping

Abstract

AbstractIn actual operation, axial flow pump stations are often used for various special purposes to meet changing needs. However, because the hydrodynamic characteristics of axial flow pump systems are still unclear when used for special purposes, there are many risks when pump systems are used for special purposes. To explore the hydrodynamic characteristics of an axial flow pump system under special utilization conditions, a high-precision full-feature test bench for an axial flow pump system is established in this paper. For the first time, an energy characteristics experiment and a pressure fluctuation measurement for a pump are carried out for a large axial flow pump system model under zero head, reverse pump and reverse power generation conditions. Then, ANSYS CFX software is used to solve the continuous equation and Reynolds average Navier–Stokes equation, combined with the SST k–ω turbulence model, and the characteristic curve and internal flow field of the pump system under special conditions are obtained. Finally, the numerical simulation results are compared with the experimental results. The results show that the velocity gradient distribution in the pump is uniform under the near zero head condition (NZHC), and there is no obvious flow collision and reflux phenomenon in the pump. Compared with the designed condition (DC), the peak-to-peak value (PPV) of pressure pulsation at the inlet of the impeller decreased by 67.16%, and the PPV at the outlet of the impeller decreased by 8.14% at H = 0 m. The maximum value of the main frequency amplitude (MFA) in the impeller area appears at the impeller inlet. Under reverse pump conditions (RPC), the phenomenon of unstable flow in the pump system is obvious, and a large range of recirculation zones appears in the nonworking face of the blade. Compared with the DC, the PPV of the impeller inlet at the optimal point of RPC increased by 122.61%, and the impeller outlet PPV increased by 11.37%. The maximum value of MFA in the impeller area appears at the impeller inlet. Under the reverse power generation condition (RPGC), no obvious flow separation was found in the nonworking face of the impeller. Compared to the DC, the PPV of the impeller inlet at the optimal point of the RPGC increased by 65.34%, and the PPV of the impeller outlet increased by 206.40%.

Funder

National Natural Science Foundation of China

Natural Science Foundation of Jiangsu Province

China Postdoctoral Science Foundation

University Science Research Project of Jiangsu Province

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3