Author:
Wang Ruipan,He Fuqiang,Chen Changping,Dai Lizong
Abstract
AbstractIn this study, a simple method was proposed to calculate electrode-sample contact impedance in the cases of two-point and four-point measurements. The results indicated that when using the saturated calcium hydroxide solution (SCH) as conductive medium, the contact impedance in the four-point measurement is negligible for the impedance range of cement-based materials. The SCH can be used as a reference for correction of the contact impedance. A reasonable combination of curing humidity and different conductive media is recommended for the two-point measurement, which is suitable for testing the ACIS of cement-based materials. In a case of contact impedance not being precisely known, it is highly recommended that a four-point measurement with two different ratios of the length of the sample and the center spacing of the voltage electrodes (L/a) should be conducted to evaluate the effect of the contact impedance following the procedure proposed in this study.
Funder
National Natural Science Foundation of China
Publisher
Springer Science and Business Media LLC
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献