Liu Chang,Klein Laura,Huang Yixing,Baader Edith,Lell Michael,Kachelrieß Marc,Maier Andreas
Abstract
AbstractTo facilitate a prospective estimation of the effective dose of an CT scan prior to the actual scanning in order to use sophisticated patient risk minimizing methods, a prospective spatial dose estimation and the known anatomical structures are required. To this end, a CT reconstruction method is required to reconstruct CT volumes from as few projections as possible, i.e. by using the topograms, with anatomical structures as correct as possible. In this work, an optimized CT reconstruction model based on a generative adversarial network (GAN) is proposed. The GAN is trained to reconstruct 3D volumes from an anterior-posterior and a lateral CT projection. To enhance anatomical structures, a pre-trained organ segmentation network and the 3D perceptual loss are applied during the training phase, so that the model can then generate both organ-enhanced CT volume and organ segmentation masks. The proposed method can reconstruct CT volumes with PSNR of 26.49, RMSE of 196.17, and SSIM of 0.64, compared to 26.21, 201.55 and 0.63 using the baseline method. In terms of the anatomical structure, the proposed method effectively enhances the organ shapes and boundaries and allows for a straight-forward identification of the relevant anatomical structures. We note that conventional reconstruction metrics fail to indicate the enhancement of anatomical structures. In addition to such metrics, the evaluation is expanded with assessing the organ segmentation performance. The average organ dice of the proposed method is 0.71 compared with 0.63 for the baseline model, indicating the enhancement of anatomical structures.
Funder
Deutsche Forschungsgemeinschaft
Friedrich-Alexander-Universität Erlangen-Nürnberg
Publisher
Springer Science and Business Media LLC
Reference22 articles.
1. Gies, M., Kalender, W. A., Wolf, H., Suess, C. & Madsen, M. T. Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies. Med. Phys. 26, 2235–2247 (1999).
2. Kalender, W. A. et al. Dose reduction in ct by on-line tube current control: Principles and validation on phantoms and cadavers. Euro. Radiol. 9, 323–328 (1999).
3. ICRP. Managing patient dose in multi-detector computed tomography (MDCT). ICRP Publication 102. Ann. ICRP vol. 37, 73–78 (2007).
4. ICRP. The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publication 103. Ann. ICRP vol. 37, 261 (2007).
5. Klein, L. et al. Patient-specific radiation risk-based tube current modulation for diagnostic CT. Med. Phys. 49, 4391–4403. https://doi.org/10.1002/mp.15673 (2022).