Monitoring blood potassium concentration in hemodialysis patients by quantifying T-wave morphology dynamics

Author:

Palmieri Flavio,Gomis Pedro,Ferreira Dina,Ruiz José Esteban,Bergasa Beatriz,Martín-Yebra Alba,Bukhari Hassaan A.,Pueyo Esther,Martínez Juan Pablo,Ramírez Julia,Laguna Pablo

Abstract

AbstractWe investigated the ability of time-warping-based ECG-derived markers of T-wave morphology changes in time ($$d_{w}$$ d w ) and amplitude ($$d_a$$ d a ), as well as their non-linear components ($${d_w^{{\mathrm{NL}}}}$$ d w NL and $${d_a^{\mathrm{NL}}}$$ d a NL ), and the heart rate corrected counterpart ($$d_{w,c}$$ d w , c ), to monitor potassium concentration ($$[K^{+}]$$ [ K + ] ) changes ($$\Delta [K^+]$$ Δ [ K + ] ) in end-stage renal disease (ESRD) patients undergoing hemodialysis (HD). We compared the performance of the proposed time-warping markers, together with other previously proposed $$[K^{+}]$$ [ K + ] markers, such as T-wave width ($$T_w$$ T w ) and T-wave slope-to-amplitude ratio ($$T_{S/A}$$ T S / A ), when computed from standard ECG leads as well as from principal component analysis (PCA)-based leads. 48-hour ECG recordings and a set of hourly-collected blood samples from 29 ESRD-HD patients were acquired. Values of $$d_w$$ d w , $$d_a$$ d a , $${d_w^{\mathrm{NL}}}$$ d w NL , $${d_a^{\mathrm{NL}}}$$ d a NL and $$d_{w,c}$$ d w , c were calculated by comparing the morphology of the mean warped T-waves (MWTWs) derived at each hour along the HD with that from a reference MWTW, measured at the end of the HD. From the same MWTWs $$T_w$$ T w and $$T_{S/A}$$ T S / A were also extracted. Similarly, $$\Delta [K^+]$$ Δ [ K + ] was calculated as the difference between the $$[K^{+}]$$ [ K + ] values at each hour and the $$[K^{+}]$$ [ K + ] reference level at the end of the HD session. We found that $$d_{w}$$ d w and $$d_{w,c}$$ d w , c showed higher correlation coefficients with $$\Delta [K^+]$$ Δ [ K + ] than $$T_{S/A}$$ T S / A —Spearman’s ($$\rho$$ ρ ) and Pearson’s (r)—and $$T_w$$ T w —Spearman’s ($$\rho$$ ρ )—in both SL and PCA approaches being the intra-patient median $$\rho \ge 0.82$$ ρ 0.82 and $$r \ge 0.87$$ r 0.87 in SL and $$\rho \ge 0.82$$ ρ 0.82 and $$r \ge 0.89$$ r 0.89 in PCA respectively. Our findings would point at $$d_{w}$$ d w and $$d_{w,c}$$ d w , c as the most suitable surrogate of $$\Delta [K^+]$$ Δ [ K + ] , suggesting that they could be potentially useful for non-invasive monitoring of ESRD-HD patients in hospital, as well as in ambulatory settings. Therefore, the tracking of T-wave morphology variations by means of time-warping analysis could improve continuous and remote $$[K^{+}]$$ [ K + ] monitoring of ESRD-HD patients and flagging risk of $$[K^{+}]$$ [ K + ] -related cardiovascular events.

Funder

AGAUR, Generalitat deCatalunya

CIBER en Bioingeniería, Biomateriales y Nanomedicina

Laboratorios Rubió

Juan de la Cierva

Ministerio de Ciencia e Innovación

European Research Council

Gobierno de Aragón, Spain

Gobierno de Aragón

Marie Sklodowska-Curie grant

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3