Abstract
AbstractAim of this study was to examine the accuracy of widely used conventional radiography-based (2D) neck-shaft angle measurements compared to 3D reconstruction. In our retrospective study, EOS 2D/3D images of 156 patients (312 limbs) were selected from our database (4–16 years old: 6 girls and 6 boys/year), where no pathology was revealed. Using the 2D modality of the EOS method neck-shaft angle was measured using the “biggest diameter” and “circle fitting” techniques to define the femoral neck axis and 1/3, 1/2 and full femur to determine the femoral shaft axis. EOS 3D reconstructions of same images were also performed and a comparison of 2D and 3D results was made. We did not find any significant difference between accuracy of the four examined 2D methods, although the deviation between 2 and 3D results was considerable (average difference: 5.11–5.58°, p < 0,001). In 31% of the cases, difference was more than 10°. Only femoral torsion showed significant influence on the difference (correlation coefficient: 0.380, p < 0.001). We did not find a clinically significant difference between the examined 2D methods, although their accuracy was highly questionable compared to 3D results. We suggest using any 3D imaging method for surgical planning and in uncertain cases.
Funder
National Research, Development, and Innovation Fund of Hungary
Thematic Excellence Program 2020—National Excellence Sub-program; Biomedical Engineering Project
Publisher
Springer Science and Business Media LLC
Reference25 articles.
1. Boese, C. K. et al. The femoral neck-shaft angle on plain radiographs: A systematic review. Skelet. Radiol. 45, 19–28. https://doi.org/10.1007/s00256-015-2236-z (2016).
2. Bizdikian, A. J. et al. Validity and reliability of different techniques of neck-shaft angle measurement. Clin. Radiol. 73(984), e981-984.e989. https://doi.org/10.1016/j.crad.2018.06.006 (2018).
3. Boese, C. K. et al. The modified femoral neck-shaft angle: Age- and sex-dependent reference values and reliability analysis. Biomed. Res. Int. 2016, 8645027. https://doi.org/10.1155/2016/8645027 (2016).
4. Teo, P. C., Kassim, A. Y. & Thevarajan, K. A 45-degree radiographic method for measuring the neck shaft angle and anteversion of the femur: A pilot study. J. Orthop. Surg. (Hong Kong) 21, 340–346. https://doi.org/10.1177/230949901302100316 (2013).