Author:
Lin Chin-Wei,Liao Shu-Hsien,Huang Han-Sheng,Wang Li-Min,Chen Jyh-Horng,Su Chia-Hao,Chen Kuen-Lin
Abstract
AbstractIn this simulation work, the linearized Bregman iterative algorithm was applied to solve the magnetic source distribution problem of a magnetic particle imaging (MPI) system for small animals. MPI system can apply an excitation magnetic field, and the induced magnetic field from the magnetic nanoparticles (MNPs) can be detected by the sensors of MPI system. With a gaussian distribution source at the upper side of the mouse brain, sensors set above the mouse brain and the constant excitation magnetic field, the average deviation of the calculated source distribution from the multiplane scanning along the axis away from the mouse brain and the closest plane scanning are 2.78 × 10–3 and 2.84 × 10–3 respectively. The simulated result showed that combination of multiplane scanning hardly improves the accuracy of the source localization. In addition, a gradient scan method was developed that uses gradient magnetic field to scan the mouse brain. The position of the maximum of the lead field matrix will be controlled by the gradient field. With a set up gaussian distribution source at the bottom of the mouse brain, the average deviation of the calculated source distribution from the gradient scan method and the constant field are 4.42 × 10–2 and 5.05 × 10–2. The location error from the two method are 2.24 × 10–1 cm and 3.61 × 10–1 cm. The simulation showed that this method can improve the accuracy compared to constant field when the source is away from the sensor and having a potential for application.
Funder
Ministry of Science and Technology, Taiwan
Publisher
Springer Science and Business Media LLC
Reference24 articles.
1. Gleich, B. & Weizenecker, J. Tomographic imaging using the nonlinear response of magnetic particles. Nature 435, 1214–1217 (2005).
2. Tanaka, S. et al. Detection of magnetic nanoparticles in lymph nodes of rat by high Tc SQUID. IEEE Tran. Appl. Supercon. 13, 377 (2003).
3. Liebl, M. et al. Magnetorelaxometry procedures for quantitative imaging and characterization of magnetic nanoparticles in biomedical applications. Biomed. Eng.-Biomed. Tech. 60, 427–443 (2015).
4. Föcke, J., Baumgarten, D. & Burger, M. The inverse problem of magnetorelaxometry imaging. Int. J. Appl. Electrom. 60, S63–S78 (2019).
5. Crevecoeur, G. et al. Advancements in magnetic nanoparticle reconstruction using sequential activation of excitation coil arrays using magnetorelaxometry. IEEE Trans. Magn. 48(4), 1 (2012).