Urinary bio-monitoring of aromatic amine derivatives by new needle trap device packed with the multi-component adsorbent

Author:

Rahimpoor Razzagh,Murtada Khaled,Firoozichahak Ali,Pashaei Babak,Soleymani-ghoozhdi Danial,Serkan Houman,Mehregan Faeze,Alizadeh Saber

Abstract

AbstractAromatic amines are a large group of chemical compounds that have attracted the attention of researchers due to their toxicity and carcinogenicity. This study aimed to develop an efficient method for sampling and analysis of aromatic amines (Aniline, N, N-dimethylaniline, 2-chloroaniline, and 3-chloroaniline) from the vapour phase (headspace) of urine samples. For the implementation of this plan, a needle trap device packed with the three-component adsorbent consisting of nano-Hydroxy Apatite (nHA), Zeolite (Ze), and Metal–Organic Framework (MOF) equipped with GC-FID was employed for the first phase. Examination of the prepared adsorbents was performed by FT-IR, PXRD, and FE-SEM techniques. The optimal value of considerable parameters such as time and temperature of extraction, salt content, and pH were established using the Response Surface Methodology-Central Composite Design (RMS-CCD) method. In this way, the optimal extraction of targeted analytes was accomplished in 41 min at 41 °C with NaCl content of 33.0% (w/v) and pH: 13.0, respectively. Also, the repeatability and reproducibility of the method were calculated to be in the range of 2.2–7.1% and 3.9–8.1%, respectively, which indicates the acceptable precision of the method. Also, the limit of detection (LOD) and limit of quantification (LOQ) were determined in the range of 0.3–32.0 ng.L−1 and 0.8–350.0 ng.L−1, respectively, which proves the high sensitivity of the proposed method. Furthermore, the recovery percent of the extracted analytes was concluded in the range of 97.0–99.0% after 6 and 30 days of the sampling and storage at 25 °C and 4 °C, respectively. Finally, the designed procedure was employed in the analysis of the above-mentioned aromatic amines in the real urine samples. The achieved results illustrate that the three-component absorbent system (nHA;Ze;MOF@NTD) can be introduced as an efficient, fast-response, sensitive, and versatile procedure for trace analysis of the different aromatic amine compounds in public and occupational health.

Funder

Gonabad University of Medical Sciences

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3