Manipulating polymer composition to create low-cost, high-fidelity sensors for indoor CO2 monitoring

Author:

Siefker Zachary A.,Hodul John N.,Zhao Xikang,Bajaj Nikhil,Brayton Kelly M.,Flores-Hansen Carsten,Zhao Wenchao,Chiu George T.-C.,Braun James E.,Rhoads Jeffrey F.,Boudouris Bryan W.

Abstract

AbstractCarbon dioxide (CO2) has been linked to many deleterious health effects, and it has also been used as a proxy for building occupancy measurements. These applications have created a need for low-cost and low-power CO2 sensors that can be seamlessly incorporated into existing buildings. We report a resonant mass sensor coated with a solution-processable polymer blend of poly(ethylene oxide) (PEO) and poly(ethyleneimine) (PEI) for the detection of CO2 across multiple use conditions. Controlling the polymer blend composition and nanostructure enabled better transport of the analyte gas into the sensing layer, which allowed for significantly enhanced CO2 sensing relative to the state of the art. Moreover, the hydrophilic nature of PEO resulted in water uptake, which provided for higher sensing sensitivity at elevated humidity conditions. Therefore, this key integration of materials and resonant sensor platform could be a potential solution in the future for CO2 monitoring in smart infrastructure.

Funder

Advanced Research Projects Agency - Energy

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Reference56 articles.

1. EPA. Report to congress on indoor air quality (Vol. 2; Report No. EPA/400/1–89/001C) (1989).

2. European Comission. Indoor air pollution: new EU research reveals higher risks than previously thought. Eur. Com. IP/03/1278 (2003).

3. Sarigiannis, D. A. Combined or multiple exposure to health stressors in indoor built environments. World Heal. Organ. Rep. Eur. 82 (2014).

4. Persily, A. & Gorfain, J. Analysis of Ventilation Data from the U.S. Environmental Protection Agency Building Assessment Survey and Evaluation (BASE) Study. NIST Interagency/Internal Report (NISTIR) 7145 (2004).

5. Shriram, S., Ramamurthy, K. & Ramakrishnan, S. Effect of occupant-induced indoor CO2 concentration and bioeffluents on human physiology using a spirometric test. Build. Environ. 149, 58–67 (2019).