Author:
Shinozaki Koichiro,Okuma Yu,Saeki Kota,Miyara Santiago J.,Aoki Tomoaki,Molmenti Ernesto P.,Yin Tai,Kim Junhwan,Lampe Joshua W.,Becker Lance B.
Abstract
AbstractUsing a new method for measuring the molecular ratio (R) of inhalation to exhalation, we investigated the effect of high fraction of inspired oxygen (FIO2) on oxygen consumption (VO2), carbon dioxide generation (VCO2), and respiratory quotient (RQ) in mechanically ventilated rats. Twelve rats were equally assigned into two groups by anesthetics: intravenous midazolam/fentanyl vs. inhaled isoflurane. R, VO2, VCO2, and RQ were measured at FIO2 0.3 or 1.0. R error was ± 0.003. R was 1.0099 ± 0.0023 with isoflurane and 1.0074 ± 0.0018 with midazolam/fentanyl. R was 1.0081 ± 0.0017 at an FIO2 of 0.3 and 1.0092 ± 0.0029 at an FIO2 of 1.0. There were no differences in VCO2 among the groups. VO2 increased at FIO2 1.0, which was more notable when midazolam/fentanyl was used (isoflurane-FIO2 0.3: 15.4 ± 1.1; isoflurane-FIO2 1.0: 17.2 ± 1.8; midazolam/fentanyl-FIO2 0.3: 15.4 ± 1.1; midazolam/fentanyl-FIO2 1.0: 21.0 ± 2.2 mL/kg/min at STP). The RQ was lower at FIO2 1.0 than FIO2 0.3 (isoflurane-FIO2 0.3: 0.80 ± 0.07; isoflurane-FIO2 1.0: 0.71 ± 0.05; midazolam/fentanyl-FIO2 0.3: 0.79 ± 0.03; midazolam/fentanyl-FIO2 1.0: 0.59 ± 0.04). R was not affected by either anesthetics or FIO2. Inspired 100% O2 increased VO2 and decreased RQ, which might be more remarkable when midazolam/fentanyl was used.
Publisher
Springer Science and Business Media LLC
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献