Distribution and associated factors of keratometry and corneal astigmatism in an elderly population

Author:

Hashemi Hassan,Aghamirsalim Mohamadreza,Hashemi Alireza,Khabazkhoob Mehdi

Abstract

AbstractTo determine the distribution of keratometry and corneal astigmatism (CA) and their association with demographic factors, systemic parameters, anthropometric measures, ocular biometric indices, and refractive errors in people aged 60 years and above. In this cross-sectional study, 160 clusters were randomly selected from Tehran city (Iran) using the multi-stage cluster sampling method. All participants underwent optometric examinations including testing uncorrected and best-corrected distance visual acuity, non-cycloplegic autorefraction, and subjective refraction. Pentacam imaging for all participants was carried out using Pentacam AXL. Keratometry and CA were reported based on Pentacam’s data. The average, standard deviation (SD) and 95% confidence interval (CI) of flat keratometry (Kf), steep keratometry (Ks), mean keratometry (mean K), and CA were 44.02 ± 1.58 D (95% CI 43.94–44.1), 44.86 ± 1.67 D (95% CI 44.78–44.94), 44.44 ± 1.58 D (95% CI 44.36–44.52), and 0.84 ± 0.74 D (95% CI 0.81–0.87), respectively. The 95% and 99% percentiles of mean K were 47.1 and 48.6 D, respectively. According to the multiple generalized estimating equation model, the mean K was significantly higher in males, in myopes, and in those with higher systolic blood pressure. Moreover, the mean K was inversely related to the axial length, height, anterior chamber depth (ACD), corneal diameter, and central corneal thickness (CCT). The prevalence of various types of CA based on a cut-off > 0.50 D was as follows; with-the-rule: 32.5% (95% CI 30.6–34.4), against-the-rule: 18.2% (95% CI 16.7–19.7), and oblique: 10.0% (95% CI 9.1–11.0). The present study investigated the normal distribution of keratometry and CA in individuals ≥ 60 years, and results can be used in clinical matters, especially in intraocular lens power calculation. Sex, systolic blood pressure, height, and some biometric components such as ACD, corneal diameter, and CCT were significantly related to keratometry and should be considered.

Publisher

Springer Science and Business Media LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3