Correlation between patient-specific quality assurance in volumetric modulated arc therapy and 2D dose image features

Author:

Guo Yixiao,Hu Jinyan,Li Yang,Ran Juntao,Cai Hongyi

Abstract

AbstractIn radiotherapy, air-filled ion chamber detectors are ubiquitously used in routine dose measurements for treatment planning. However, its use has been restricted by intrinsic low spatial resolution barriers. We developed one procedure for patient-specific quality assurance (QA) in arc radiotherapy by coalescing two adjacent measurement images into a single image to improve spatial resolution and sampling frequency, and investigated how different spatial resolutions affect the QA results. PTW 729 and 1500 ion chamber detectors were used for dosimetric verification via coalescing two measurements with 5 mm-couch shift and the isocenter, and only isocenter measurement, which we call coalescence and standard acquisition (SA). Statistical process control (SPC), process capability analysis (PCA), and receiver operating characteristic (ROC) curve were used to compare the performance of the two procedures in determining tolerance levels and identifying clinically relevant errors. By analyzing 1256 γ values calculated on interpolated data points, our results indicated that detector 1500 showed higher averages in coalescence cohorts at different tolerance criteria and the dispersion degrees were spread out smaller. Detector 729 yielded a slightly lower process capability of 0.79, 0.76, 1.10, and 1.34, but detector 1500 exhibited somewhat different results of 0.94, 1.42, 1.19, and 1.60 in magnitude. The results of SPC individual control chart showed that cases in coalescence cohorts with γ values lowering its lower control limit (LCL) were greater than those in SA cohorts for detector 1500. A combination of the width of multi-leaf collimator (MLC) leaf, the cross-sectional area of the single detector, and the spacing between adjacent detectors might lead to discrepancies in percent γ values across diverse spatial resolution scenarios. The accuracy of reconstructed volume dose is mainly determined by the interpolation algorithm used in dosimetric systems. The magnitude of filling factor in the ion chamber detectors determined its ability to detect dose deviations. SPC and PCA results indicated that coalescence procedure could detect more potential failure QA results than SA while enhancing action thresholds.

Funder

Natural Science Foundation of Gansu province

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3