Metasurfaces of capacitively loaded metallic rings for magnetic resonance imaging surface coils

Author:

Freire Manuel J.

Abstract

AbstractThis work investigates the use of a metasurface made up of a two-dimensional array of capacitively loaded metallic rings to enhance the signal-to-noise ratio of magnetic resonance imaging surface coils and to tailor the magnetic near-field radio frequency pattern of the coils. It is found that the signal-to-noise ratio is increased if the coupling between the capacitively loaded metallic rings in the array is increased. The input resistance and the radiofrequency magnetic field of the metasurface loaded coil are numerically analyzed by means of an efficient algorithm termed the discrete model to determine the signal-to-noise ratio. Standing surface waves or magnetoinductive waves supported by the metasurface introduce resonances in the frequency dependence of the input resistance. The signal-to-noise ratio is found to be optimal at the frequency corresponding to a local minimum existing between these resonances.The discrete model is used in an optimization procedure to fit the structural parameters of a metasurface to enhance the signal-to-noise ratio at the frequency corresponding to this local minimum in the input resistance. It is found that the signal-to-noise ratio can be greatly improved if the mutual coupling between the capacitively loaded metallic rings of the array is made stronger by bringing them closer or by using rings of squared shape instead of circular. These conclusions derived from the numerical results provided by the discrete model are double-checked by means of numerical simulations provided by the commercial electromagnetic solver Simulia CST and by experimental results. Numerical results provided by CST are also shown to demonstrate that the surface impedance of the array of elements can be adjusted to provide a more homogeneous magnetic near-field radio frequency pattern that ultimately leads to a more uniform magnetic resonance image at a desired slice. This is achieved by preventing the reflection of propagating magnetoinductive waves at the edges of the array by matching the elements arranged at the edges of the array with capacitors of suitable value.

Funder

Ministerio de Ciencia e Innovación/Agencia Estatal de Investigación

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3