Chen Shun-Qiang,Li Li,Gao Bu-Lang,Wu Qiao-Wei,Shao Qiu-Ji,Wang Zi-Liang,Zhang Kun,Li Tian-Xiao
Abstract
AbstractTo investigate the safety and short-term effect of Pipeline Flex devices in the treatment of complex unruptured intracranial aneurysms, a retrospective study was performed for patients with complex unruptured intracranial aneurysms who were treated with the Pipeline Flex embolization device (PED Flex device) combined with or without coiling. The clinical, endovascular, and follow-up data were analyzed. One hundred and thirty-one patients with 159 complex unruptured cerebral aneurysms were treated with the PED Flex device, with 144 Flex devices deployed. Periprocedural complications occurred in four patients, resulting in the complication rate of 3.1%, including ischemic complications in three patients (2.3%) and hemorrhagic complication in one (0.8%). At discharge, the mRS was 0 in 101 (77.1%) patients, 1 in 25 (19.1%), 2 in four (3.1%), and 4 in one (0.8%), with the good prognosis rate (mRS 0–2) of 99.2%. Clinical follow-up was carried out in 87 (66.4%) patients 3–42 months after the procedure, with the mRS of 0 in 78 (89.7%), 1 in five (5.7%), 2 in three (3.4%), and 4 in one (1.1%). No significant (P = 0.16) difference existed in the mRS at discharge compared with that at clinical follow-up. Angiographic follow-up was performed in 61 (46.7%) patients with 80 (50.3%) aneurysms at 3–40 months, with the OKM grade of D in 57 (71.3%) aneurysms, C in eight (10%), and B in 15 (18.8%). Asymptomatic instent stenosis occurred in four patients (6.6%). In conclusion: The treatment of complex intracranial aneurysms with the Pipeline Flex embolization device may be safe and effective, with a high complete occlusion rate, a decreased complication rate, and a good prognosis rate at medium follow-up.
Funder
Henan Province Science and Technology Key Project
13th Five year Plan of China for Research and Development
Publisher
Springer Science and Business Media LLC
Reference38 articles.
1. Harland, T. A. et al. Comparative analysis of unruptured cerebral aneurysm treatment outcomes and complications with the classic versus flex pipeline embolization devices and phenom versus marksman microcatheter delivery system: The role of microcatheter choice on complication rate. J. Vasc. Interv. Neurol. 11, 13–18 (2020).
2. Kang, H. et al. Pipeline embolization device for intracranial aneurysms in a large chinese cohort: Complication risk factor analysis. Neurotherapeutics 18(2), 1198–1206. https://doi.org/10.1007/s13311-020-00990-8 (2021).
3. Oguz, S., Tabakci, O. N., Uysal, E., Bulut, E. & Dinc, H. Pipeline flex embolization device (ped flex) for the treatment of intracranial aneurysms: Periprocedural outcomes and first-year angiographic results. Turk. J. Med. Sci. 49, 1640–1646 (2019).
4. Trivelato, F. P. et al. Safety and effectiveness of the pipeline flex embolization device with shield technology for the treatment of intracranial aneurysms: Midterm results from a multicenter study. Neurosurgery 87, 104–111 (2020).
5. Becske, T. et al. Pipeline for uncoilable or failed aneurysms: Results from a multicenter clinical trial. Radiology 267, 858–868 (2013).
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献