Abstract
AbstractOccupational exposure to toluene is associated with health risks that require reliable monitoring methods. Hippuric acid (HA), a urinary metabolite of toluene, serves as a valuable biomarker for such exposure. Colorimetric methods for the quantitative determination of HA have gained prominence due to their simplicity, cost-effectiveness, and suitability for field application. In the present study, a simple colorimetric technique was optimized for the determination of HA in the urine sample, and compared with a usual HPLC technique. The central composite design (CCD) was applied to examine the effective parameters on the colorimetric determination of HA. The calibration curve for HA was established within the concentration range of 6 to 100 mg L−1 with R2 = 0.97. The detection limit (LOD) and quantification limit (LOQ) were determined to be 1.8 mg L−1 and 6 mg L−1 respectively. The relative standard deviation (RSD%) was less than 5%, and the recovery% (R%) was 90.5–100.1. The overall results showed good agreement between the colorimetric and HPLC results. There was a significant relationship between the results obtained from HPLC and colorimetric methods especially for higher concentration levels of HA (≥ 500 mg/g creatinine). In conclusion, our optimized colorimetric method is a simple, cost-effective, and rapid method for determination of HA in occupational exposure, which is comparable with the HPLC technique.
Funder
Shiraz University of Medical Sciences
Publisher