The effect of Ding’s screws and tension band wiring for treatment of olecranon fractures: a biomechanical study

Author:

Zhao Yong,Tian Hongbo,Yin Nuo,Du Li,Pan Mingmang,Ding Liang

Abstract

AbstractAlthough tension band wiring (TBW) is popular and recommended by the AO group, the high rate of complications such as skin irritation and migration of the K-wires cannot be ignored. Ding’s screw tension band wiring (DSTBW) is a new TBW technique that has shown positive results in the treatment of other fracture types. The objective of this study was to evaluate the stability of DSTBW in the treatment of olecranon fractures by biomechanical testing. We conducted a Synbone biomechanical model by using three fixation methods: DSTBW, intramedullary screw and tension band wiring (IM-TBW), and K-wire TBW, were simulated to fix the olecranon fractures. We compared the mechanical stability of DSTBW, IM-TBW, and TBW in the Mayo Type IIA olecranon fracture Synbone model using a single cycle loading to failure protocol or pullout force. During biomechanical testing, the average fracture gap measurements were recorded at varying flexion angles in three different groups: TBW, IM-TBW, and DSTBW. The TBW group exhibited measurements of 0.982 mm, 0.380 mm, 0.613 mm, and 1.285 mm at flexion angles of 0°, 30°, 60°, and 90° respectively. The IM-TBW group displayed average fracture gap measurements of 0.953 mm, 0.366 mm, 0.588 mm, and 1.240 mm at each of the corresponding flexion angles. The DSTBW group showed average fracture gap measurements of 0.933 mm, 0.358 mm, 0.543 mm, and 1.106 mm at the same flexion angles. No specimen failed in each group during the cyclic loading phase. Compared with the IM-TBW and TBW groups, the DSTBW group showed significant differences in 60° and 90° flexion angles. The mean maximum failure load was 1229.1 ± 110.0 N in the DSTBW group, 990.3 ± 40.7 N in the IM-TBW group, and 833.1 ± 68.7 N in the TBW group. There was significant difference between each groups (p < 0.001).The average maximum pullout strength for TBW was measured at 57.6 ± 5.1 N, 480.3 ± 39.5 N for IM-TBW, and 1324.0 ± 43.8 N for DSTBW. The difference between maximum pullout strength of both methods was significant to p < 0.0001. DSTBW fixation provides more stability than IM-TBW and TBW fixation models for olecranon fractures.

Publisher

Springer Science and Business Media LLC

Reference34 articles.

1. Wilkerson, J. A. & Rosenwasser, M. P. Surgical techniques of olecranon fractures. J. Hand Surg. Am. 39(8), 1606–1614 (2014).

2. Duckworth, A. D., Clement, N. D., Aitken, S. A., Court-Brown, C. M. & McQueen, M. M. The epidemiology of fractures of the proximal ulna. Injury 43(3), 343–346 (2012).

3. Matar, H. E., Ali, A. A., Buckley, S., Garlick, N. I. & Atkinson, H. D. Surgical interventions for treating fractures of the olecranon in adults. Cochrane Database Syst. Rev. 2014(11), CD010144 (2014).

4. Mu È ller, M.E., Allgo È wer, W., Willengger, H., editors. Manual of Internal Fixation. Techniques Recommended by the AO-Group. New York: Springer, 1970.

5. Weber, B. G. & Vasey, H. Osteosynthese, BEI OLEKRANONFRAKTUR [OSTEOSYNTHESIS IN OLECRANON FRACTURES]. Z Unfallmed Berufskr 56, 90–96 (1963).

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3