In vitro surface analysis of the brushing resistance of orthodontic sealants using two different profilometric evaluation methods

Author:

Lorenz J.,Schidtmann I.,Morawietz M.,Kiesow A.,Wehrbein H.,Sarembe S.,Erbe C.

Abstract

AbstractThe enamel can be protected by applying orthodontic sealants at the bracket base to avoid the development of white spot lesions caused by inadequate oral hygiene. The aim of this study was to investigate the mechanical resistance of five commonly used orthodontic sealants against brushing in comparison to a positive group. Hydroxyapatite discs were bonded with a metal bracket and a piece of arch-wire was ligated in order to simulate a daily clinical situation (n = 48). Samples were divided into 6 groups of respectively 8 specimens. Sealants were applied around the bracket base according to manufacturer’s instructions. Following sealants were used: Group 1: Pro Seal (Reliance Orthodontic Products, Itasca, Illinois, USA); 2: Light Bond (Reliance Orthodontic Products, Itasca, Illinois, USA); 3: ClinproXT Varnish (3M ESPE, Seefeld, Germany); 4: ProtectoCaF2 Nano (BonaDent GmbH, Frankfurt am Main, Germany); 5: Fluor Protector and 6: Tetric EvoFlow (both Ivoclar Vivadent AG, Schaan Liechtenstein). Tooth brushing were simulated for 6 weeks and 6 months with an electric toothbrush. The sealant thickness was measured by mechanical (MP) and optical profilometry (OP) at baseline, after 6 weeks and after 6 months of brushing. Statistical analysis was performed according to two mixed linear models and post hoc Tukey–Kramer comparisons. The significance level was set at 5% (α ≤ 0.05). Pro Seal (MP: 9%; OP: 22%) and Light Bond (MP: 19%; OP: 16%) showed the lowest changes in sealant thickness after 6 months of simulated brushing. ClinproXT Varnish and Tetric EvoFlow recorded no statistically significant results (p > 0.05). The fluoride varnishes ProtectoCaF2 Nano and Fluor Protector could not be conclusively evaluated since the thickness of the sealants could not be determined at baseline. The results of both evaluation methods MP and OP are in good agreement. Pro Seal and Light Bond were resistant against tooth brushing and were able to adequately keep the bracket environment sealed even after 6 months. The two different measuring methods, MP and OP, provide a precise impression of the changes in the surface.

Funder

Universitätsmedizin der Johannes Gutenberg-Universität Mainz

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3