A bench study on the prevention of lung-to-lung aspiration with double-lumen endobronchial tubes and bronchial blockers

Author:

Kim Hyerim,Seol Taikyung,Han Sung-Hee,Kim Honghyeon,Hwang Jin-Young

Abstract

AbstractEffective lung isolation prevents lung-to-lung aspiration during thoracotomy for the management of hemoptysis. Double-lumen endobronchial tubes (DLT) and bronchial blockers are commonly used for lung separation during thoracic surgery. In this study, the fluid-sealing characteristics of the endobronchial cuffs of three different commercially available DLTs (Broncho-Cath with a polyvinylchloride cuff, Broncho-Cath with a polyurethane cuff, and Human Broncho with a silicone cuff) and two different bronchial blockers (Arndt and Coopdech bronchial blockers) were evaluated using a benchtop model. The lateral decubitus position for the surgical management of bleeding from the right lung was simulated. The artificial tracheobronchial tree was placed horizontally, with the left bronchus in the dependent position and the right bronchus in the non-dependent position. In the DLT experiments, the tracheobronchial tree was intubated with left-sided DLTs, and the endobronchial cuff was inflated to maintain the intracuff pressure at 25 cmH2O. In the experiments with bronchial blockers, each bronchial blocker was inserted into the right bronchus, and the endobronchial cuff was inflated to seal the main bronchus. A fluid leakage test around the endobronchial cuff was performed using three different types of DLT (size 35, 37, and 41 Fr, each) and two different types of bronchial blockers (9 Fr). The 5 mL of colored water was poured into the right bronchus to simulate the blood flow from the operative side, and the times to the first and 100% leakage around the endobronchial cuff were recorded. Each bronchial blocker showed significantly less leakage over time than the other DLTs (P < 0.05). Fluid was not fully leaked around the cuffs for 24 h with either bronchial blocker. The times to first and 100% leakage were not significantly different among different types of DLTs. The times to first and 100% leakage did not also differ among the three different sizes of each type DLT. There was no significant difference in the time to first leakage around the endobronchial cuffs between Arndt and Coopdech bronchial blockers. Bronchial blockers provided a more effective seal against lung-to-lung aspiration than DLTs in the lateral decubitus position for thoracotomy in the benchtop model.

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3