Low-dose CBCT reconstruction via joint non-local total variation denoising and cubic B-spline interpolation

Author:

Lee Ho,Park Jiyoung,Choi Yeonho,Park Kyung Ran,Min Byung Jun,Lee Ik Jae

Abstract

AbstractThis study develops an improved Feldkamp–Davis–Kress (FDK) reconstruction algorithm using non-local total variation (NLTV) denoising and a cubic B-spline interpolation-based backprojector to enhance the image quality of low-dose cone-beam computed tomography (CBCT). The NLTV objective function is minimized on all log-transformed projections using steepest gradient descent optimization with an adaptive control of the step size to augment the difference between a real structure and noise. The proposed algorithm was evaluated using a phantom data set acquired from a low-dose protocol with lower milliampere-seconds (mAs).The combination of NLTV minimization and cubic B-spline interpolation rendered the enhanced reconstruction images with significantly reduced noise compared to conventional FDK and local total variation with anisotropic penalty. The artifacts were remarkably suppressed in the reconstructed images. Quantitative analysis of reconstruction images using low-dose projections acquired from low mAs showed a contrast-to-noise ratio with spatial resolution comparable to images reconstructed using projections acquired from high mAs. The proposed approach produced the lowest RMSE and the highest correlation. These results indicate that the proposed algorithm enables application of the conventional FDK algorithm for low mAs image reconstruction in low-dose CBCT imaging, thereby eliminating the need for more computationally demanding algorithms. The substantial reductions in radiation exposure associated with the low mAs projection acquisition may facilitate wider practical applications of daily online CBCT imaging.

Funder

Yonsei University College of Medicine for 2019

Basic Science Research Program through the National Research Foundation of Korea funded by the Ministry of Education

Korea Health Technology R

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. 4D-Precise: Learning-based 3D motion estimation and high temporal resolution 4DCT reconstruction from treatment 2D+t X-ray projections;Computer Methods and Programs in Biomedicine;2024-06

2. Low Dose CBCT Denoising Using a 3D U-Net;2024 IEEE International Conference on Acoustics, Speech, and Signal Processing Workshops (ICASSPW);2024-04-14

3. A non-local image denoising method based on TV-L1 with variable exponents;Fourteenth International Conference on Graphics and Image Processing (ICGIP 2022);2023-06-27

4. Impact of Denoising on Deep-Learning-Based Automatic Segmentation Framework for Breast Cancer Radiotherapy Planning;Cancers;2022-07-22

5. Differential epithelial and stromal LGR5 expression in ovarian carcinogenesis;Scientific Reports;2022-07-01