Author:
Lee Chang-Lae,Hong Key Jo,Kim Namwoo,Han Kwanhee,Kim Dongkyu,Jung Hoe-Su,Lee Sangmin,Park Junyoung,Lee Kyoung-Yong,Lee Jee Eun,Choi Yuna,Cho Minkook
Abstract
AbstractIn this study, preclinical experiments were performed with an in-house developed prototypal photon-counting detector computed tomography (PCD CT) system. The performance of the system was compared with the conventional energy-integrating detector (EID)-based CT, concerning the basic image quality biomarkers and the respective capacities for material separation. The pre- and the post-contrast axial images of a canine brain captured by the PCD CT and EID CT systems were found to be visually similar. Multi-energy images were acquired using the PCD CT system, and machine learning-based material decomposition was performed to segment the white and gray matters for the first time in soft tissue segmentation. Furthermore, to accommodate clinical applications that require high resolution acquisitions, a small, native, high-resolution (HR) detector was implemented on the PCD CT system, and its performance was evaluated based on animal experiments. The HR acquisition mode improved the spatial resolution and delineation of the fine structures in the canine’s nasal turbinates compared to the standard mode. Clinical applications that rely on high-spatial resolution expectedly will also benefit from this resolution-enhancing function. The results demonstrate the potential impact on the brain tissue segmentation, improved detection of the liver tumors, and capacity to reconstruct high-resolution images both preclinically and clinically.
Publisher
Springer Science and Business Media LLC
Reference34 articles.
1. Shikhaliev, P., Xu, T. & Molloi, S. Photon counting CT: Concept and initial results. Med. Phys. 32, 427–436 (2005).
2. Gutjahr, R. et al. Human imaging with photon-counting-based CT at clinical dose levels: Contrast-to-noise ratio and cadaver studies. Invest. Radiol. 51, 421 (2016).
3. Byl, A. et al. Photon-counting normalized metal artifact reduction (NMAR) in diagnostic CT. Med. Phys. 48, 3572–3582 (2021).
4. Silva, J. et al. Resolution characterization of a silicon-based, photon-counting computed tomography prototype capable of patient scanning. J. Med. Imaging (Bellingham) 6, 043502 (2019).
5. Ji, X. et al. Development of an integrated C-arm interventional imaging system with a strip photon counting detector and a flat panel detector. IEEE Trans. Med. Imaging https://doi.org/10.1109/TMI.2021.3095419 (2021).