Continued versus Suspended Cardiac Resynchronization Therapy after Left Ventricular Assist Device Implantation

Author:

Roukoz Henri,Bhan Adarsh,Ravichandran Ashwin,Ahmed Mustafa M.,Bhat Geetha,Cowger Jennifer,Abdullah Munazzah,Dhawan Rahul,Trivedi Jaimin R.,Slaughter Mark S.,Gopinathannair Rakesh

Abstract

AbstractCardiac resynchronization therapy (CRT) improves outcomes in heart failure patients with wide QRS complex. However, CRT management following continuous flow Left Ventricular Assist Device (LVAD) implant vary: some centers continue CRT while others turn off the left ventricular (LV) lead at LVAD implant. We sought to study the effect of continued CRT versus turning off CRT pacing following continuous flow LVAD implantation. A comprehensive retrospective multicenter cohort of 295 patients with LVAD and pre-existing CRT was studied. CRT was programmed off after LVAD implant in 44 patients. We compared their outcomes to the rest of the cohort using univariate and multivariate models. Mean age was 60 ± 12 years, 83% were males, 52% had ischemic cardiomyopathy and 54% were destination therapy. Mean follow-up was 2.4 ± 2.0 years, and mean LVAD support time was 1.7 ± 1.4 years. Patients with CRT OFF had a higher Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) mean profile (3.9 vs 3.3, p = 0.01), more secondary prevention indication for a defibrillator (64.9% vs 44.5%, p = 0.023), and more pre-LVAD ventricular arrhythmias (VA) (77% vs 60%, p = 0.048). There were no differences between the CRT OFF and CRT ON groups in overall mortality (Log rank p = 0.32, adjusted HR = 1.14 [0.54–2.22], p = 0.71), heart transplantation, cardiac and noncardiac mortality, all cause hospitalizations, hospitalizations for ICD shocks, and number and frequency of ICD shocks or anti-tachycardia pacing therapy. There were no differences in post LVAD atrial arrhythmias (AA) (Adjusted OR = 0.45 [0.18–1.06], p = 0.31) and ventricular arrhythmias (OR = 0.65 [0.41–1.78], p = 0.41). There was no difference in change in LVEF, LV end diastolic and end systolic diameters between the 2 groups. Our study suggests that turning off CRT pacing after LVAD implantation in patients with previous CRT pacing did not affect mortality, heart transplantation, device therapies or arrhythmia burden. A prospective study is needed to confirm these findings.

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3