Radiation dose evaluation of pediatric patients in CT brain examination: multi-center study

Author:

Eddy Fotso Kamdem,Ngano Samba Odette,Jervé Fotue Alain,Serge Abogo

Abstract

AbstractThere is currently no Pediatric Regulatory Diagnostic Reference Level (DRL) in Cameroon to standardize protocols in hospitals. France, a European country, has DRL allowing them to optimize their examination protocol. For the sake of radiation protection, we have proposed to evaluate the dose and acquisition parameters delivered to our pediatric patients to optimize the protocols used. We also compared the 75th percentile values of dose parameters by acquisition between the three hospitals to Diagnostic Reference Level (DRL) of France. In this retrospective and evaluative multicenter study, a total of 320 patients who had at least one cranial CT scan were enrolled from three medical centers. The CT acquisition parameters including tube potential (kV), tube current (mA), slice Thickness (T), spiral or sequential scanning techniques, volume CT dose index (CTDIvol), and dose length product (DLP) were analyzed. CTDIvol values in our centers were found up to 17.42%, 46.01%, 21.56% respectively for children aged 1–4 higher than values of France's DRL. For those aged 5–9, we obtained 44.58%, 43.15%, 42.21% respectively. In addition, for children aged 10–14 there are also up to 47.73%, 44.11%, 46.39% respectively higher than values of France's DRL. It is similary for DLP values. The study showed a significant dosimetric overshoot compared to the France’s DRL and prompted us to make corrections to the protocols used and to a more rigorous monitoring of the principles of radiation protection and optimization rules in pediatric computed tomography in our hospitals. Our results have led us to make changes to our protocols which are the subject of a new dosimetric evaluation. The development of DRL for improving the pediatric CT scan in our country is necessary to optimize our protocols. Our results have led us to make changes to our protocols which are the subject of a new dosimetric evaluation. It would be necessary to set up a quality control structure in Cameroon and their applications in current practice.

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Reference32 articles.

1. International Commission on Radiological Protection Radiological protection in medicine. ICRP Publication 105. Ann ICRP 37, 1–64 (2007).

2. International Commission on Radiological Protection 1990. Recommendations of the International Commission on Radiological Protection. ICRP Publication 60. Ann ICRP 21, 1–201 (1991).

3. International Commission on Radiological Protection. Radiological protection and safety in medicine. ICRP Publication 73. Ann ICRP 26, 1–47 (1996).

4. International Commission on Radiological Protection. Diagnostic reference levels in medical imaging: review and additional advice. ICRP Supporting Guidance 2. Ann ICRP 31, 33–52 (2001).

5. JORF Arrêté du 24 octobre 2011 relatif aux niveaux de référence diagnostiques en radiologie et en médecine nucléaire. Paris, France (2012).