Impact of COVID-19 on the association between pulse oximetry and arterial oxygenation in patients with acute respiratory distress syndrome

Author:

Nguyen Lee S.,Helias Marion,Raia Lisa,Nicolas Estelle,Jaubert Paul,Benghanem Sarah,Ait Hamou Zakaria,Dupland Pierre,Charpentier Julien,Pène Frédéric,Cariou Alain,Mira Jean-Paul,Chiche Jean-Daniel,Jozwiak Mathieu

Abstract

AbstractManaging patients with acute respiratory distress syndrome (ARDS) requires frequent changes in mechanical ventilator respiratory settings to optimize arterial oxygenation assessed by arterial oxygen partial pressure (PaO2) and saturation (SaO2). Pulse oxymetry (SpO2) has been suggested as a non-invasive surrogate for arterial oxygenation however its accuracy in COVID-19 patients is unknown. In this study, we aimed to investigate the influence of COVID-19 status on the association between SpO2 and arterial oxygenation. We prospectively included patients with ARDS and compared COVID-19 to non-COVID-19 patients, regarding SpO2 and concomitant arterial oxygenation (SaO2 and PaO2) measurements, and their association. Bias was defined as mean difference between SpO2 and SaO2 measurements. Occult hypoxemia was defined as a SpO2 ≥ 92% while concomitant SaO2 < 88%. Multiple linear regression models were built to account for confounders. We also assessed concordance between positive end-expiratory pressure (PEEP) trial-induced changes in SpO2 and in arterial oxygenation. We included 55 patients, among them 26 (47%) with COVID-19. Overall, SpO2 and SaO2 measurements were correlated (r = 0.70; p < 0.0001), however less so in COVID-19 than in non-COVID-19 patients (r = 0.55, p < 0.0001 vs. r = 0.84, p < 0.0001, p = 0.002 for intergroup comparison). Bias was + 1.1%, greater in COVID-19 than in non-COVID-19 patients (2.0 vs. 0.3%; p = 0.02). In multivariate analysis, bias was associated with COVID-19 status (unstandardized β = 1.77, 95%CI = 0.38–3.15, p = 0.01), ethnic group and ARDS severity. Occult hypoxemia occurred in 5.5% of measurements (7.7% in COVID-19 patients vs. 3.4% in non-COVID-19 patients, p = 0.42). Concordance rate between PEEP trial-induced changes in SpO2 and SaO2 was 84%, however less so in COVID-19 than in non-COVID-19 patients (69% vs. 97%, respectively). Similar results were observed for PaO2 regarding correlations, bias, and concordance with SpO2 changes. In patients with ARDS, SpO2 was associated with arterial oxygenation, but COVID-19 status significantly altered this association.

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3