Author:
Matar Kamal M.,Alshemmari Salem H.,Refaat Samar,Anwar Alia
Abstract
AbstractBusulfan (Bu) is an alkylating agent commonly used in preparative regimens for hematologic malignant and non-malignant patients undergoing hematopoietic stem cell transplantation (HSCT). The objective of the present study was to develop an UPLC-MS/MS method for quantification of Bu in human plasma. A total of 55 patients with hematologic malignancies (n = 34) and non- malignancies (n = 21) received myeloablative Bu therapy prior to HSCT. A tandem mass spectrometric method was developed and validated to quantify Bu levels in these patients. The method was fully validated over the concentration range of 25–2000 ng/mL (r > 0.99). The assay method demonstrated good precision and accuracy. Stability studies indicated that the drug was stable in various conditions. Incurred sample reanalysis findings were within acceptable ranges (<15% of the nominal concentration). Based on the 1st dose AUC results, one third of hematologic malignant patients and half of non-malignant patients needed dose adjustment. However, in subsequent doses (5th, 9th, and 13th), 77%, 82% and 82%, respectively, of hematologic malignant patients and 71%, 67% and 86%, respectively, of non-malignant patients achieved the target range of Bu AUC. The suitability of the developed method for routine TDM of Bu in HSCT patients was demonstrated. The study suggests that the pharmacokinetic profile of Bu varies in both groups.
Publisher
Springer Science and Business Media LLC
Cited by
12 articles.