Abstract
AbstractGastric Function has been successfully estimated by gastric electrical impedance tomography (gEIT) Suit with dual-step fuzzy clustering. The gEIT Suit which are made of elastic cloth with dual-planar electrodes and compact data acquisition (DAQ) system measures gastric impedance Z to visualize the gastric conductivity distribution σ. The dual-step fuzzy clustering extracts the clustered gastric conductivity distribution kσ, which accurately estimates the gastric function. The gEIT Suit with dual-step fuzzy clustering are applied to eight healthy persons during liquid meal consumption to estimate the gastric function under gastric accommodation phase of 200, 400 and 600 mL based on the gastric emptying phase. As the results, the gEIT Suit successfully estimate the gastric function. By the measured impedance Z, the subjects have a mean temporal impedance $$\overline{\Delta \mathbf{Z} }$$
Δ
Z
¯
= − 9.27 [Ohm] and p-value of that $$\overline{\mathbf{Z} }$$
Z
¯
p(Z) = 0.0013[–]as the t-test result. In the case of gastric conductivity distribution σ, the subjects have a value of spatial mean conductivity distribution ⟨σ⟩ = 0.23[–] and p-value of that ⟨σ⟩ p(σ) = 0.0140[–]. Lastly, in the case gastric volume V, subjects have a gastric volume V = 12.44 [%] and p-value p(V) = 0.0664[–].
Funder
Japan Society for the Promotion of Science
Publisher
Springer Science and Business Media LLC
Reference20 articles.
1. Buisman, W. J. et al. Evaluation of gastric volumes: Comparison of 3-D ultrasound and magnetic resonance imaging. Ultrasound Med. Biol. 42(7), 1423–1430 (2016).
2. Bisinotto, F. M. B. et al. Use of ultrasound for gastric volume evaluation after ingestion of different volumes of isotonic solution. Braz. J. Anesthesiol. 67(4), 376–382 (2017).
3. Clarrett, D. M. & Hachem, C. Gastroesophageal refl ux disease aff ects millions of people worldwide with significant clinical implications. Mo Med. 115(3), 214–218 (2018).
4. Soulsby, C. T. et al. Measurements of gastric emptying during continuous nasogastric infusion of liquid feed: Electric impedance tomography versus gamma scintigraphy. Clin. Nutr. 25(4), 671–680 (2006).
5. Karamichou, E., Richardson, R. I., Nute, G. R., McLean, K. A. & Bishop, S. C. Genetic analyses of carcass composition, as assessed by X-ray computer tomography, and meat quality traits in scottish blackface sheep. Anim. Sci. 82(2), 151–162 (2006).
Cited by
11 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献