Effectiveness of one-shot dual-energy subtraction chest radiography with flat-panel detector in distinguishing between calcified and non-calcified nodules

Author:

Minato Kojiro,Yamazaki Motohiko,Yagi Takuya,Hirata Tetsuhiro,Tominaga Masaki,You Kyoryoku,Ishikawa Hiroyuki

Abstract

AbstractThe purpose of this study was to evaluate the added value of the soft tissue image obtained by the one-shot dual-energy subtraction (DES) method using a flat-panel detector compared with the standard image alone in distinguishing calcified from non-calcified nodules on chest radiographs. We evaluated 155 nodules (48 calcified and 107 non-calcified) in 139 patients. Five radiologists (readers 1 − 5) with 26, 14, 8, 6 and 3 years of experience, respectively, evaluated whether the nodules were calcified using chest radiography. CT was used as the gold standard of calcification and non-calcification. Accuracy and area under the receiver operating characteristic curve (AUC) were compared between analyses with and without soft tissue images. The misdiagnosis ratio (false positive plus false negative ratios) when nodules and bones overlapped was also examined. The accuracy of all radiologists increased after adding soft tissue images (readers 1 − 5: 89.7% vs. 92.3% [P = 0.206], 83.2% vs. 87.7% [P = 0.178], 79.4% vs. 92.3% [P < 0.001], 77.4% vs. 87.1% [P = 0.007], and 63.2% vs. 83.2% [P < 0.001], respectively). AUCs for all the readers improved, except for reader 2 (readers 1 − 5: 0.927 vs. 0.937 [P = 0.495], 0.853 vs. 0.834 [P = 0.624], 0.825 vs. 0.878 [P = 0.151], 0.808 vs. 0.896 [P < 0.001], and 0.694 vs. 0.846 [P < 0.001], respectively). The misdiagnosis ratio for nodules that overlapped with the bone decreased after adding soft tissue images in all readers (11.5% vs. 7.6% [P = 0.096], 17.6% vs. 12.2% [P = 0.144], 21.4% vs. 7.6% [P < 0.001], 22.1% vs. 14.5% [P = 0.050] and 35.9% vs. 16.0% [P < 0.001], respectively), particularly that of readers 3 − 5. In conclusion, the soft tissue images obtained using one-shot DES with a flat-panel detector have added value in distinguishing calcified from non-calcified nodules on chest radiographs, especially for less experienced radiologists.

Publisher

Springer Science and Business Media LLC

Subject

Multidisciplinary

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3