Author:
Kim Hyun-Jung,Jang Ji-Hyun,Kim Sun-Young
Abstract
AbstractAlthough mineral trioxide aggregates (MTA) have been adopted as an endodontic sealer because of excellent sealing effect and bioactive property and been modified with improvement of its characteristics, the developed MTA sealers have not yet satisfied all the ideal requirements of endodontic sealers. The aim of this study was to assess the characteristics of elastin-like polypeptide (ELP)-incorporated MTA for use as an endodontic sealer and compare them with those of commercial MTA sealers. Two commercial MTA sealers and three experimental ELP-incorporated MTA sealers with 0.3, 0.4, and 0.5 liquid/powder (L/P) ratio for 10 wt% ELP liquid were evaluated. The push-out bond strength, flow rate, sealer penetrability and wash-out resistance were tested and the sealer-dentin interface was observed using a scanning electron microscope (SEM). Our study revealed the ELP-incorporated MTA sealer, especially in 0.4 L/P ratio, exhibited the higher push-out bond strength and flow rate (P < 0.05), and equal or superior sealer penetration and remarkable wash-out resistance compared to commercial MTA sealers. The groups of ELP-based experimental sealers also exhibited more intimate contact with dentin compared to the commercial MTA sealers. Our research will suggest the possible adoption of the ELP-incorporated MTA as endodontic sealer for clinical use.
Funder
National Research Foundation of Korea
New Faculty Startup Fund from Seoul National University
Publisher
Springer Science and Business Media LLC
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献